Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEPRISA FOOD EQUIPMENT, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DEPRISA FOOD EQUIPMENT, LLC in 13151 SYLVIA ANDREA DR., SAN ELIZARIO, TX 79849 (NAICS 423440). OSHA activity number 342455821.

Watch Deprisa Food Equipment, LLC — free Get an email when a new federal OSHA severe-injury report for Deprisa Food Equipment, LLC is published. One employer, no account, unsubscribe in one click.
Site address
13151 SYLVIA ANDREA DR.
City
SAN ELIZARIO
State
TX
ZIP
79849
Mailing
13151 SYLVIA ANDREA DR., SAN ELIZARIO, TX 79849
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423440
Employees
11
Ownership type
A

11 citations on file for this inspection.

1910.215 A04

Serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3500.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support off hand grinding work:     On or about July 10, 2017, bench grinders were not provided with work rest(s); this condition exposed employees to struck-by hazards in the following instances;      a) In Shop #1, the Hantover Bench Grinder was missing its work rest.    b) In Shop #2, the Central Machinery Bench Grinder was missing its work rest.    c) In Shop #3, the Bradford Metal Master Bench Grinder was missing its work rest.     d) In Shop #4, the Stanley Bench Grinder was missing its work rest.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5070

1910.215 B09

Serious Gravity 10 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  On or about July 10, 2017, bench grinders were not provided with tongue guard(s); this condition exposed employees to struck-by hazards in the following instances;    a) In Shop #1, the Hantover Bench Grinder was missing tongue guard(s).  b) In Shop #2, the Central Machinery Bench Grinder was missing tongue guard(s).  c) In Shop #3, the Bradford Metal Master Bench Grinder was missing tongue guard(s).   d) In Shop #4, the Stanley Bench Grinder was missing tongue guard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3500.00 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):     On or about July 10, 2017, three bench grinders did not have safety guards; this condition exposed employees to struck-by hazards in the following instances;    a) In Shop #1, the Hantover Bench Grinder did not have safety guard(s).    b) In Shop #2, the Central Machinery Bench Grinder did not have safety guard(s).    c) In Shop #4, the Stanley Bench Grinder did not have safety guard(s).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5070

1910.243 C03

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3500.00 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s):    On or about July 10, 2017, in shop #3, abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s); this condition exposed employees to struck-by hazards in the following instances;    a) Makita (Model GA4030/Serial No. 554851Y) did not have a safety guard.    b) Hitachi (Model G12SE2/Serial No. M440275) did not have a safety guard.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5070

1910.305 B01 I

Serious Gravity 5 3 instances 11 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $1950.00 Reduced
1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed.      On or about July 10, 2017, conductors entering the receptacle boxes  located under the Central Machinery Bench Grinder in the shop #2 were not protected from abrasion and the openings through which the conductors entered were not effectively closed. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3622

1910.303 B02

Serious Gravity 5 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.  On or about July 10, 2017, listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling in the following instances; this condition exposed employees to electrical shock hazards;   a) A metal receptacle box installed on the outside wall of Shop #1 was not in accordance with any instructions included in the listing and labeling.  b) In shop #2, romex wiring running along the outside of the pillar and into the receptacle boxes underneath the Central Machinery Bench Grinder was not installed in accordance with any instructions included in the listing and labeling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02

Serious Gravity 5 3 instances 11 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $1950.00 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.    On or about July 10, 2017, receptacle boxes in completed installations did not have a cover or faceplate in the following instances; this condition exposed employees to electrical shock hazards.    a) In Shop #3 the receptacle box on the northwest wall next to the door leading to Shop #2 was missing a faceplate.    b) In Shop #1, two receptacle boxes on north wall leading to Shop #2 were missing a faceplates.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3622

1910.23 E01 VII

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $406.00 · Current $400.00 Reduced
29 CFR 1910.23(e)(1)(vii): Mobile ladder stands and platforms did not have wheels or casters equipped with a system to impede horizontal movement when an employee is on the stand or platform:    On or about July 10, 2017, in the warehouse; the caster mechanism on the mobile ladder platform was broken and did not impede the horizontal movement. This condition exposed employee to fall hazards.
Recent events (2)
  • — I (O) $400
  • — Z (O) $406

1910.253 B02 II

Other-than-serious 8 instances 4 exposed
Issued
Abate by
Penalty
Initial $406.00 · Current $400.00 Reduced
29 CFR 1910.253(b)(2)(ii):   Cylinders were not stored in areas to ensure that the cylinders would not be knocked over:    On or about July 10, 2017, LPG and Acetylene compressed gas cylinders stored by the warehouse were not secured as to prevent them from falling.  This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $400
  • — Z (O) $406

1910.244 A01 II

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $406.00 · Current $400.00 Reduced
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means.    On or about July 10, 2017, the load capacity of two hydraulic pallet jacks were not marked.  This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (O) $400
  • — Z (O) $406

1910.303 B07 I

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $406.00 · Current $400.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.    On or about July 10, 2017, in Shop #1; an unused opening on phase converter and welder power control box was left unprotected. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $400
  • — Z (O) $406

UNFI

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342455821.