Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: METRO STORAGE, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of METRO STORAGE, LLC in 18 WILMINGTON WEST CHESTER PIKE, CHADDS FORD, PA 19317 (NAICS 236220). OSHA activity number 342457231.

Watch Metro Storage, LLC — free Get an email when a new federal OSHA severe-injury report for Metro Storage, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
METRO STORAGE, LLC
Site address
18 WILMINGTON WEST CHESTER PIKE
City
CHADDS FORD
State
PA
ZIP
19317
Mailing
13528 BOULTON BOULEVARD, LAKE FOREST, IL 60045
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
500
Ownership type
A

6 citations on file for this inspection.

1926.451 B08

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $12675.00 · Current $7605.00 Reduced
29 CFR 1926.451(b)(8): At all points of a scaffold where the platform changes direction, such as turning a corner, the platform that rests on a bearer at an angle other than a right angle was not laid first, and platforms which rest at right angles over the same bearer were not laid second, on top of the first platform:    (a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The platforms used by employees as bridges were laid on top of the working platforms that rested at right angles.  Employees were performing masonry work on the scaffold at a height of approximately 25 feet above the lower level and used the bridges to traverse between scaffold platforms and to and from the access ladder and were thus exposed to fall hazards.  This condition was observed on July 5, 2017.
Recent events (3)
  • — F (O) $7605
  • — C (S) $12675
  • — Z (S) $12675

1926.451 G04 IV

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7696.00 · Current $4618.00 Reduced
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:    (a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The employer did not ensure that midrails were installed on the working level of a fabricated frame scaffold, thus exposing employees to fall hazards. This condition was observed on July 5, 2017.
Recent events (3)
  • — F (O) $4617.6
  • — C (S) $7696
  • — Z (S) $7696

1926.451 H01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall.    (a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The employer did not install toeboards or other devices on an erected scaffold to protect employees working below from falling tools and materials, thus exposing employees to struck-by hazards.  This condition was observed on July 5, 2017.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.652 A01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9234.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The employer did not ensure that employees performing concrete work in an excavation that was approximately 5 feet 2 inches deep were protected from cave-ins by an adequate protective system, thus exposing employees to struck-by and caught-in hazards.  This condition was observed on July 5, 2017.
Recent events (3)
  • — F (S) $0
  • — C (S) $9234
  • — Z (S) $9234

1926.1053 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The employer allowed the use of a portable step ladder that was approximately four feet tall as a means of access into and out of an excavation that was approximately five feet 2 inches deep.  The side rails of the ladder were below the upper landing surface, thus exposing employees to fall hazards.  This condition was observed on July 5, 2017.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B04

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) 18 Wilmington West Chester Pike, Chadds Ford, PA 19317 - The employer allowed the use of a portable step ladder as a means of access into and out of an excavation.  The step ladder was used in the closed position, thus exposing employees to fall hazards.  This condition was observed on July 5, 2017.
Recent events (3)