Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHAWN CULLEN & RYAN DUPERE DBA MINUTEMAN CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHAWN CULLEN & RYAN DUPERE DBA MINUTEMAN CONSTRUCTION in 2170 MAIN STREET, BUFFALO, NY 14214 (NAICS 238160). OSHA activity number 342493277.

Watch Shawn Cullen & Ryan Dupere DBA Minuteman Construction — free Get an email when a new federal OSHA severe-injury report for Shawn Cullen & Ryan Dupere DBA Minuteman Construction is published. One employer, no account, unsubscribe in one click.
Site address
2170 MAIN STREET
City
BUFFALO
State
NY
ZIP
14214
Mailing
101 ARMIN PLACE, BUFFALO, NY 14210
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2716.00 · Current $1500.00 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:      a) On or about 07/24/17, on the main roof and front dormer roof on a house at 2170 Main St., Buffalo, NY:  Two employees engaged in roofing work on a steep roof were exposed to a fall of approx.  9 to 21 foot  to the porch roof or the ground below.  No fall protection system was being utilized. Pitch of the main roof was approx. 8 in 12.       NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2716

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $1500.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) On or about 07/24/17, at the front of the house at 2170 Main St., Buffalo, NY:  Employees used an extension ladder to access the porch roof which was approx.  12 ft. above the ground. The side rails of that ladder only extended approx.  20 inches above the porch roof.        NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2173

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342493277.