PUTNAM, CT —
OSHA Inspection: STEVE BOUSQUET'S APPLIANCE & T.V., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STEVE BOUSQUET'S APPLIANCE & T.V., INC. in 6 LIVERY STREET, PUTNAM, CT 06260 (NAICS 443111). OSHA activity number 342515327.
Where did this inspection happen?
- Establishment
- STEVE BOUSQUET'S APPLIANCE & T.V., INC.
- Site address
- 6 LIVERY STREET
- City
- PUTNAM
- State
- CT
- ZIP
- 06260
- Mailing
- 16 FURNACE STREET, DANIELSON, CT 06239
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 443111
- Employees
- 14
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.37 B02
- Issued
- Penalty
- Initial $1847.00 · Current $924.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Showroom: On, or about, August 1, 2017, signs were not provided for the front and rear exit doors.
Recent events (2)
- — I (S) $923.5
- — Z (S) $1847
1910.303 B02
- Issued
- Penalty
- Initial $1847.00 · Current $924.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A. Couch Area: On, or about August 31, 2017, a duplex box designed for permanent mounting was hanging from a vertical column by armored cable. B. Front Desk: On, or about August 31, 2017, a duplex box designed for permanent mounting was laying on the floor. C. Front Desk: On, or about, August 31, 2017, a relocatable power tap was energized through an extension cord. Power taps are required to be energized by direct connection to a receptacle.
Recent events (2)
- — I (S) $923.5
- — Z (S) $1847
1910.334 A03 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles: Front Desk: On, or about, August 1, 2017, a relocatable power tap used for the computer system was energized through a two-wire extension cord. The ground prong provided on the male plug for the power tap was hanging over the edge of the female receptacle on the extension cord.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07
- Issued
- Penalty
- Initial $1847.00 · Current $924.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner Couch Area: On, or about, August 1, 2017, nonmetallic sheathed cable (romex) that was used to energize an overhead light fixture had several inches of the outer jacket missing at the male plug connection, exposing the inner coated conductors.
Recent events (2)
- — I (S) $923.5
- — Z (S) $1847
1910.334 A03 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(3)(iii): Adapters which interrupt the continuity of the equipment grounding connection were used: Couch Area: On, or about, August 1, 2017, an overhead light fixture was plugged into a receptacle through a cheater plug that was designed to allow a three wire male plug to be inserted into a two wire female outlet. Because the grounding conductor on the cheater plug was not attached the cover screw on the female outlet, the path to ground was not continuous.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07 IV
- Issued
- Penalty
- Initial $2463.00 · Current $1232.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: Couch Area: On, or about, August 1, 2017, the wall mounted receptacle that was used to energize a red extension cord to test appliances was not secured in the wall.
Recent events (2)
- — I (S) $1231.5
- — Z (S) $2463
1910.305 B02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose and each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: In the following locations, on, or about August 1, 2017, electrical boxes were not provided with a cover: A. Couch Area: Wall mounted outlet used to test appliances. B. Couch Area: A duplex receptacle hanging near the vertical column. C. Rear of Showroom: A ceiling mounted junction box. D. Rear of Showroom, Near Ramp: A junction box mounted to the left of the door opening. E. Couch Area, above main aisle: A ceiling mounted junction box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 J07 IV
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1811.00 Reduced
General-duty citation text
29 CFR 1910.1001(j)(7)(iv): The employer did not provide to all employees who perform housekeeping work in areas where ACM and/or PACM is present, an asbestos awareness training course covering the health effects of asbestos; and/or locations of ACM and/or recognition of ACM and PACM damage and deterioration and/or requirements in this standard related to housekeeping, and/or proper response to fiber release episodes: Training: Showroom: On, or about, August 1, 2017, employee(s) who were assigned housekeeping duties where asbestos or presumed asbestos containing pipe insulation was located had not been provided with information and training regarding the hazards of asbestos and proper housekeeping procedures.
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.1001 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1001(k)(1): All surfaces were not maintained as free as practicable of ACM waste and debris and accompanying dust: Showroom: On, or about, August 1, 2017, asbestos insulation provided on pipes was friable and pieces were falling onto merchandise and onto the floor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 K04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1001(k)(4): The employer did not use vacuuming equipment with high-efficiency particulate air (HEPA) filters for vacuuming asbestos containing waste and/or debris: Showroom: On, or about, August 1, 2017, a Bissel Powerforce Helix Turbo upright vacuum cleaner used to vacuum the rugs each week was not provided with a HEPA filter.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1001(k)(6): Waste, scrap, debris, bags, containers, equipment, and clothing contaminated with asbestos consigned for disposal, were not collected and disposed of in sealed impermeable bags, or other closed, impermeable containers: Showroom: On, or about, August 1, 2017, debris that was swept from the floor was pushed into a backroom where cardboard was stored. It was left on the floor until the cardboard was cleaned out the room bi-monthly.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition. Front Desk: On, or about, August 1, 2017, an electrical cord was run across the access to/egress from the desk, creating a tripping hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.22 A03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(3): Walking-working surfaces were not maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice: Floor Near Restroom: On, or about, August 1, 2017, soft/rotten wood in the floor created a tripping hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 443111)
SEATTLE, WA—2026-06-11
WA317991639 - ALBERT LEE INC
PORTLAND, OR—2026-04-14
317743820 - JBC LIMITED LLC
KENT, WA—2025-02-25
WA317984745 - WANDERS INC
HIGH POINT, NC—2024-12-13
157980 - HOME DEPOT U.S.A., INC.
PORTLAND, OR—2024-05-22 00:00:00
317736541 - JBC LIMITED LLC
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342515327.