SALEM, IL —
OSHA Inspection: BETTENDORF STANFORD HOLDINGS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BETTENDORF STANFORD HOLDINGS, INC. in 1370 W MAIN ST, SALEM, IL 62881 (NAICS 333294). OSHA activity number 342517877.
Where did this inspection happen?
- Establishment
- BETTENDORF STANFORD HOLDINGS, INC.
- Site address
- 1370 W MAIN ST
- City
- SALEM
- State
- IL
- ZIP
- 62881
- Mailing
- 1370 W MAIN ST, SALEM, IL 62881
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333294
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4183.00 · Current $3137.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts: Blade Room, at the Grinding Machines, employees performing blade grinding operations were exposed to nip point hazards where the saw blades travelled across the two idler rollers.
Recent events (2)
- — I (S) $3137
- — Z (S) $4183
1910.305 E02
- Issued
- Abate by
- Penalty
- Initial $5577.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: In the Blade Room, the 110 volt electrical switches for the coolant on each of the Grinding Machines were not designed for wet locations.
Recent events (2)
- — I (O) $0
- — Z (S) $5577
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $5577.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: In the Blade Room, flexible cords were supplying power to the 110 volt electrical switches for the coolant on each of the Grinding Machines, instead of installing permanent wiring located within conduit.
Recent events (2)
- — I (O) $0
- — Z (S) $5577
More inspections at BETTENDORF STANFORD HOLDINGS, INC.
SALEM, IL—2017-08-02 00:00:00
BETTENDORF STANFORD HOLDINGS, INC.
SALEM, IL—2014-05-14 00:00:00
BETTENDORF STANFORD HOLDINGS, INC.
View BETTENDORF STANFORD HOLDINGS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333294)
PORTLAND, OR—2026-05-20
317744212 - MACHINE PRODUCTS INC
WINSTED, MN—2026-05-11
111213 - TETRA PAK PROCESSING EQUIPMENT INC
EUGENE, OR—2025-09-29
317741921 - COMMERCIAL DEHYDRATORS SYSTEMS LLC
MINNEAPOLIS, MN—2025-08-06
109616 - MILL CITY ROASTERS LLC
COKATO, MN—2025-07-31
109591 - ADVANCED PROCESS TECHNOLOGIES, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342517877.