Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BETTENDORF STANFORD HOLDINGS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BETTENDORF STANFORD HOLDINGS, INC. in 1370 W MAIN ST, SALEM, IL 62881 (NAICS 333294). OSHA activity number 342517877.

Watch Bettendorf Stanford Holdings, INC. — free Get an email when a new federal OSHA severe-injury report for Bettendorf Stanford Holdings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1370 W MAIN ST
City
SALEM
State
IL
ZIP
62881
Mailing
1370 W MAIN ST, SALEM, IL 62881
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333294
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 5 instances 12 exposed
Issued
Abate by
Penalty
Initial $4183.00 · Current $3137.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts:    Blade Room, at the Grinding Machines, employees performing blade grinding operations were exposed to nip point hazards where the saw blades travelled across the two idler rollers.
Recent events (2)
  • — I (S) $3137
  • — Z (S) $4183

1910.305 E02

Other-than-serious 5 instances 15 exposed
Issued
Abate by
Penalty
Initial $5577.00 · Current $0.00 Reduced
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures:    In the Blade Room, the 110 volt electrical switches for the coolant on each of the Grinding Machines were not designed for wet locations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5577

1910.305 G01 IV A

Other-than-serious 5 instances 15 exposed
Issued
Abate by
Penalty
Initial $5577.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:     In the Blade Room, flexible cords were supplying power to the 110 volt electrical switches for the coolant on each of the Grinding Machines, instead of installing permanent wiring located within conduit.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5577

View BETTENDORF STANFORD HOLDINGS, INC.'s full OSHA safety record →