Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JUAN DELGADO DBA JUAN DELGADO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JUAN DELGADO DBA JUAN DELGADO in 975 N. LAKEVIEW PARKWAY, VERNON HILLS, IL 60061 (NAICS 238160). OSHA activity number 342525862.

Watch Juan Delgado DBA Juan Delgado — free Get an email when a new federal OSHA severe-injury report for Juan Delgado DBA Juan Delgado is published. One employer, no account, unsubscribe in one click.
Site address
975 N. LAKEVIEW PARKWAY
City
VERNON HILLS
State
IL
ZIP
60061
Mailing
1136 MODEIRA STREET, INDIANAPOLIS, IN 46203
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $305.00 · Current $305.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Juan Delgado dba Juan Delgado, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                01                                   08/14/2017  01                                02                                   08/14/2017  01                                03                                   08/14/2017  01                                04                                   08/14/2017   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $305

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $2173.00
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:            a) On or about August 3, 2017, employees were exposed to eye injury while operating pneumatic nail guns without the benefit of eye protection.           In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2173

1926.501 B13

Serious Gravity 10 6 instances 6 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):             a) On or about August 3, 2017, employees were exposed to the hazard of falling while working from a pitched roof surface at an elevation of approximately 3 stories without the benefit of fall protection.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

1926.1053 B04

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:    a) On or about August 3, 2017,  A section of an aluminum extension ladder was tied to an aluminum extension ladder for the purpose of increasing the working height of the ladder.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3803

1926.1053 B16

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:     a) On or about August 3, 2017, a portable extension ladder was provided for use with broken rungs.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2716