FAIRVIEW, NJ —
OSHA Inspection: JEFF DUROCHER ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JEFF DUROCHER ROOFING in 175 ANDERSON AVENUE, FAIRVIEW, NJ 07022 (NAICS 238160). OSHA activity number 342526274.
Where did this inspection happen?
- Establishment
- JEFF DUROCHER ROOFING
- Site address
- 175 ANDERSON AVENUE
- City
- FAIRVIEW
- State
- NJ
- ZIP
- 07022
- Mailing
- 3 STEPHEN PLACE, LITTLE FALLS, NJ 07424
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $3259.00 · Current $1955.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: A) Exterior, On Scaffold: An employee was exposed to eye/face injuries while using a pneumatic nail gun and was not protected with any type of eye/face protection, on or about July 18, 2017.
Recent events (2)
- — I (S) $1955.4
- — Z (S) $3259
1926.451 C03
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: A) Exterior on Scaffold - Employees were exposed to fall hazards/scaffold collapse hazards of approximately 30 feet while working on a pump jack scaffold that was not braced on the bottom, on or about July 18th, 2017.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.451 F06
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. A) Exterior, On scaffold: Employees were exposed to electrocution hazards while working on a scaffold approximately 2 feet away from an energized, un-insulated secondary power line, on or about July 18th, 2017. B)Exterior, On scaffold: Employees were exposed to electrocution hazards while working on a scaffold approximately 3 feet away from an energized, un-insulated primary power line, on or about July 18th, 2017.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.451 G01
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level shall be protected from falling to that lower level. A) Exterior on Scaffold - Employees were exposed to fall hazards of approximately 30 feet while working on a pump jack scaffold that was not protected by a complete guardrail system, or any other type of fall protection on or about July 18th, 2017.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
More inspections at JEFF DUROCHER ROOFING
GARFIELD, NJ—2011-04-21 00:00:00
JEFF DUROCHER ROOFING
View JEFF DUROCHER ROOFING's full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source