GONZALES, TX —
OSHA Inspection: E BARR FEEDS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E BARR FEEDS, INC. in 212 ST. LOUIS ST., GONZALES, TX 78629 (NAICS 444220). OSHA activity number 342564077.
Where did this inspection happen?
- Establishment
- E BARR FEEDS, INC.
- Site address
- 212 ST. LOUIS ST.
- City
- GONZALES
- State
- TX
- ZIP
- 78629
- Mailing
- 212 ST. LOUIS ST., GONZALES, TX 78629
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444220
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.272 G01 II
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $1630.00 Reduced
General-duty citation text
29 CFR 1910.272(g)(1)(ii): Prior to entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not deenergized, disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods. During the annual cleaning in May 2017, the employer did not require machine lock out inside the storage bin while employees cleaned out the corn. Failure to de-energize and lock out equipment exposes employees to the hazards of being struck by equipment such as, but not limited to the sweep auger.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about August 18, 2017, and at times prior thereto, the employer did not establish an energy control program to include training and periodic inspections, exposing employees to the hazard of being struck by or caught in machines and/or equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.272 G01 III
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $1630.00 Reduced
General-duty citation text
29 CFR 1910.272(g)(1)(iii): The atmosphere within a bin, silo, or tank in the grain handling facility was not tested for oxygen content prior to employee entry: During the annual cleaning in May 2017, the employer did not test for the presence of combustible gases, vapors, toxic agents and sufficient oxygen content, exposing employees to potential atmospheric hazards.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $978.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating: On or about August 18, 2017, and at times prior thereto, there was a broken electrical conduit on #2 grain bin motor, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $978
- — Z (S) $1630
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about August 18, 2017, the employer was using an industrial fan where the end of the cord was not equipped with strain relief and the insulated wires were exposed, exposing the employee to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 444220)
HOUSTON, TX—2026-06-26
PLANTS FOR ALL SEASONS
GRESHAM, OR—2026-06-18
317744543 - COASTAL FARM & HOME SUPPLY LLC
SPOKANE, WA—2026-06-10
WA317991606 - NWSP SELLER CORP
SAINT PAUL, MN—2026-06-04
111365 - EGG/PLANT URBAN FARM SUPPLY CO
ISANTI, MN—2026-05-28
111340 - NORTHLAND LANDSCAPE SUPPLY - NURSERY INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source