BREWERTON, NY —
OSHA Inspection: STEVE FLEMING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of STEVE FLEMING in 35 NORTH RIVER ROAD, BREWERTON, NY 13029 (NAICS 238160). OSHA activity number 342565363.
Where did this inspection happen?
- Establishment
- STEVE FLEMING
- Site address
- 35 NORTH RIVER ROAD
- City
- BREWERTON
- State
- NY
- ZIP
- 13029
- Mailing
- 9 FLOYD DRIVE, WEST MONROE, NY 13167
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $3803.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on or about 8/21/17: Workers were stripping roofing material on a 5:12 pitch roof with a ground to eave height of 15 feet at the front and 10 feet at the rear, without fall protection of any kind.
Recent events (2)
- — I (S) $0
- — Z (S) $3803
1926.1053 B01
- Issued
- Penalty
- Initial $2716.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, on or about 8/21/17: Workers were accessing a 5:12 pitch roof with a ground to eave height of 15 feet with an extension ladder that did not extend at least 3 feet above the upper landing. b) At the jobsite, on or about 8/21/17: Workers were accessing a 5:12 pitch roof with a ground to eave height of 10 feet with an extension ladder that did not extend at least 3 feet above the upper landing.
Recent events (2)
- — I (S) $0
- — Z (S) $2716
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.