Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JMS INSULATION, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of JMS INSULATION, INC. in 6415 W DEMPSTER ST., MORTON GROVE, IL 60053 (NAICS 238310). OSHA activity number 342569530.

Watch JMS Insulation, INC. — free Get an email when a new federal OSHA severe-injury report for JMS Insulation, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6415 W DEMPSTER ST.
City
MORTON GROVE
State
IL
ZIP
60053
Mailing
8607 S KEELER AVE, CHICAGO, IL 60652
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
10
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1500.00 Reduced

Hazardous substances P125

29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.    29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employees or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with required worksite-specific procedures:    a) On August 27, 2017, JMS Insulation, Inc. did not ensure that a written respiratory protection program was established and implemented for those employees required to wear respiratory protection, including tight-fitting, supplied air respirator(s).    The respiratory protection program shall include, at a minimum, procedures for selecting respirators; medical evaluations; fit testing; procedures for proper use in routine and reasonably foreseeable emergency situations; procedures for cleaning, storing, inspecting, repairing and discarding respirators; employee training regarding respiratory hazards they are exposed to, proper uses and limitations of respirators; and procedures for regularly evaluating the effectiveness of the respirator program.
Recent events (3)
  • — F (S) $1500
  • — C (S) $2716
  • — Z (S) $2716

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances P125

29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.  29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) On August 27, 2017, JMS Insulation, Inc. did not provide a medical evaluation to employee(s) before tight-fitting, supplied air respirator(s) were required to be worn in the workplace.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances P125

29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.  29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  (a) On August 27, 2017, JMS Insulation, Inc. did not ensure that all employees required to wear tight-fitting, supplied air respirator(s), were provided with an annual fit test.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 D01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1500.00 Reduced

Hazardous substances P125

29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter.    29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:    (a) On August 22, 2017, JMS Insulation, Inc. did not ensure that the selected respiratory protection, including the tight-fitting, supplied-air respirator was NIOSH certified. The Strong China M70 respirator provided to the employees was not a NIOSH certified respirator.
Recent events (3)
  • — F (S) $1500
  • — C (S) $2716
  • — Z (S) $2716

1910.1200 E01

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1000.00 Reduced

Hazardous substances P125

29 CFR 1926.59: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.1200 of this chapter.    29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) On August, 27, 2017, JMS Insulation, Inc. did not maintain a written hazard communication program in accordance with 29 CFR 1910.1200(e)(1) that would describe or include at least the following:    1) Requirement for labeling of containers of hazardous chemicals;  2) Material safety data sheet availability;  3) Training of employees;  4) A complete list of hazardous chemicals known to be in the workplace;  5) Methods to inform employees of the hazards on non-routine tasks; and  6) Methods to inform other employer(s) of material safety data sheet availability; the labeling system; and any precautionary measures to protect employees.    Employees were exposed to hazardous chemicals, including, but not limited to Polymeric Methylene Diphenyl Diisocyanate.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2716
  • — Z (S) $2716

1910.1200 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances P125

29 CFR 1926.59: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.1200 of this chapter.  29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) On August 27, 2017, JMS Insulation, Inc. did not provide employee(s) training on the chemicals in their workplace including Polymeric Methylene Diphenyl Diisocyanate.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342569530.