Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DONATO CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DONATO CONSTRUCTION, LLC. in 540 STABLE STREET LOT 4945, MARYSVILLE, OH 43040 (NAICS 238130). OSHA activity number 342582004.

Watch Donato Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for Donato Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
540 STABLE STREET LOT 4945
City
MARYSVILLE
State
OH
ZIP
43040
Mailing
1469 PINELAND COURT, COLUMBUS, OH 43223
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a. On or before August 24, 2017 where an employee was on the roof using a nail gun to attach sheathing to the roof and a circular saw to trim the sheathing, the employees eyes were not protected, thereby being exposed to struck-by hazards.
Recent events (1)
  • — Z (S) $2716

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. On or before August 28, 2017 where an employee was sheathing the roof, the employee was not protected from falls, thereby being exposed to a 18 foot fall hazard.
Recent events (1)
  • — Z (S) $2716

1926.502 D15

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached.  a. On or before August 24, 2017 where an employee was sheathing the roof of a two story house, the fall protection rope that was being used was wrapped around the truss and nail plate, thereby exposing the employees to a 18 foot fall hazard.