LUBBOCK, TX —
OSHA Inspection: WILMER MALDONADO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WILMER MALDONADO in 9202 TURNER AVE., LUBBOCK, TX 79424 (NAICS 238140). OSHA activity number 342607538.
Where did this inspection happen?
- Establishment
- WILMER MALDONADO
- Site address
- 9202 TURNER AVE.
- City
- LUBBOCK
- State
- TX
- ZIP
- 79424
- Mailing
- 5918 117TH ST., LUBBOCK, TX 79424
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.300 A
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition: Employees operating an unguarded grinder with a frayed electrical cord were exposed to amputation and electrical shock hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1630
1926.405 G02 III
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: Employees using a spliced flexible cord to operate a grinder to cut brick were exposed to electrical shock hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1630
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $3259.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Employees performing masonry work from a scaffold structure that was not fully planked were exposed to an unprotected fall of over 10 feet to the ground below.
Recent events (2)
- — I (S) $1500
- — Z (S) $3259
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: Employees performing masonry work from a scaffold structure that did not have base plates in several locations were exposed to an unprotected fall hazard of over 10 feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Employees performing masonry work from a scaffold structure that had not been inspected for defects before beginning work were exposed to an unprotected fall of over 10 feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Employees performing masonry work from a scaffold structure that had not been erected under the supervision and direction of a competent person qualified in scaffold erection were exposed to an unprotected fall of over 10 feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C04
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur. Employees performing masonry work from a scaffold structure that was not secured with locking pins were exposed to an unprotected fall hazard of over 10 feet to the ground below.
Recent events (2)
- — I (S) $700
- — Z (S) $2173
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Employees performing masonry work from a scaffold structure had not been trained to recognize hazards associated with scaffolds and the procedures to follow to minimize those hazards.
Recent events (2)
- — I (S) $700
- — Z (S) $2173
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. Employees involved with the erecting of a scaffold structure had not been trained to recognize hazards associated with the scaffolding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Employees engaged in roofing work without fall protection were exposed to fall hazards in excess of six feet.
Recent events (2)
- — I (S) $1500
- — Z (S) $3803
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342607538.