Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOREST SERVICE, RIPPLEBROOK FIRE WAREHOUSE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREST SERVICE, RIPPLEBROOK FIRE WAREHOUSE in 59868 HWY. 224, ESTACADA, OR 97023 (NAICS 924120). OSHA activity number 342613189.

Watch Forest Service, Ripplebrook Fire Warehouse — free Get an email when a new federal OSHA severe-injury report for Forest Service, Ripplebrook Fire Warehouse is published. One employer, no account, unsubscribe in one click.
Site address
59868 HWY. 224
City
ESTACADA
State
OR
ZIP
97023
Mailing
16400 CHAMPION WAY, SANDY, OR 97055
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
200
Ownership type
D

18 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems.  (a) Barlow Ranger District, Ranger Station, Engine Bay North Side, Dufur, OR:  On or about October 11th, 2017 and at times prior thereto, the employer exposed employees to a fall of approximately 7' while working on the exterior north side of the Engine Bay Building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A06

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were maintained in a legible condition:  (a) Hood River Ranger District, Parkdale Work Center, Machine Shop, Mount Hood Parkdale, OR:  On or about October 10th 2017 and at times prior thereto, the employer did not ensure all name plates and markings were maintained in a legible condition for the operator's controls on the Clark forklift, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(1) One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  (a) Barlow Ranger District, Ranger Station, Woodshop, Dufur, OR:  On or about October 11th, 2017 and at times prior thereto, the employer did not ensure the Makita Miter Saw (model LS1000 serial 93389E) was equipped with an adequate guard. This exposed employees to severe lacerations and amputation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(1): Circular hand-fed ripsaw was not guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut.  (a) Zigzag Ranger District, Carpentry Shop, Zigzag, OR:  On or about August 30th, 2017 and at times prior thereto, the employer did not ensure that the Rockwell Unisaw guard was in use at all times, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw were not provided with non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut.  (a) Zigzag Ranger District, Carpentry Shop, Zigzag, OR:  On or about August 30th, 2017 and at times prior thereto, the employees were using the Rockwell Unisaw to rip wood with an improperly installed anti-kickback device.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1960.8 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1960.8(a): The head of each agency did not furnish to each employee, employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm.  (a) Barlow Ranger District, Ranger Station, Woodshop, Dufur, OR:  On or about October 11th, 2017 and at times prior thereto, the employer did not ensure that the Sears Craftsman pedestal grinder model 397.19360 serial 025500317, with an abrasive wheel, was not used for side grinding. Grinding wheels with excessive and deliberate side contact can become off balanced and can explode causing deep lacerations and puncture wounds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B02 I

Repeat Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface.  (a) Barlow Ranger District, Ranger Station, Engine Bay North Side Second Floor, Dufur, OR:  On or about October 11, 2017 and at times prior thereto, the employer did not ensure that the ramp leading into the engine bay building had the required midrails. This exposed employees to a fall of approximately 12'.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.23(e)(1), which was contained in OSHA inspection number 1055218, notice number 2, item number 1 and was affirmed as a final order on 11/2/2015, with respect to a workplace located at Prairie City Ranger District.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.23(e)(1), which was contained in OSHA inspection number 978142, citation number 1, item number 1 and was affirmed as a final order on 12/15/2014, with respect to a workplace located at Deschutes National Forest Supervisor's Office.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.213 B03

Repeat Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(b)(3): The employer did not ensure that the drill press was equipped with a device to prevent the machine from automatically restarting upon restoration of power after a power failure.  (a) Hood River Ranger District, Parkdale Work Center, Carpenter's Shop, Mount Hood Parkdale, OR:  On or about October 10th, 2017 and at times prior thereto, the employer did not ensure that the RIDGID Drill Press model DP15000 was equipped with an anti-restart device.    The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(b)(3), which was contained in OSHA inspection number 978154, citation number 2, item number 1 and was affirmed as a final order on 12/11/2014, with respect to a workplace located at Bend Pine Administration Site.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(b)(3), which was contained in OSHA inspection number 898288, citation number 1, item number 1 and was affirmed as a final order on 05/14/2013, with respect to a workplace located at Rigdon Flatcreek Facility.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.215 B09

Repeat Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch.   (a) Zigzag Ranger District, North Compound Fire Warehouse, Zigzag, OR:  On or about August 30th, 2017 and at times prior thereto, the employer did not ensure that the upper tongue guards, on the Cummins 8" bench grinder, were installed properly.  This prevents the guards from being adjusted as the diameter of the wheel is reduced from usage.  Contact with an exploding grinding disc can cause severe lacerations and deep puncture wounds.   The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.215(b)(9), which was contained in OSHA inspection number 1055280, citation number 2, item number 1 and was affirmed as a final order on 07/09/2015, with respect to a workplace located at Burns Interagency Communication Center.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.215(b)(9), which was contained in OSHA inspection number 978154, citation number 2, item number 2 and was affirmed as a final order on 12/11/2014, with respect to a workplace located at Bend Pine Administration Site.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.242 B

Repeat Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air was used for cleaning purposes and was not reduced to less than 30 p.s.i.  (a) Zigzag Ranger District, North Compound, Fire Warehouse, Zigzag, Or:  On or about August 30th, 2017 and at times prior thereto, employees used a compressed air cleaning nozzle without an adequate pressure reducer. Contact with compressed air is likely to cause pneumatic lacerations and foreign objects in the eyes.  (b) Zigzag Ranger District, North Compound, Construction and Maintenance Building, Zigzag, OR:  On or about August 31st, 2017 and at times prior thereto, employees used a compressed air cleaning nozzle without an adequate pressure reducer. Contact with compressed air is likely to cause pneumatic lacerations and foreign objects in the eyes.   The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 1055280, citation number 2, item number 2 and was affirmed as a final order on 07/09/2015, with respect to a workplace located at Burns Interagency Communication Center.   The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 978154 , citation number 2, item number 2 and was affirmed as a final order on 12/11/2014, with respect to a workplace located at Bend Pine Administration.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.305 B01 II

Repeat Gravity 5 3 instances 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.       (a) Clackamas Ranger District, Ripplebrook Fire Warehouse, Garage, Estacada, OR:  On or about August 29th, 2017 and at times prior thereto, the employer exposed employees to contact with live electrical due to a missing knockout approximately one inch in diameter on an electrical junction box.    (b) Barlow Ranger District, Clear Lake Lookout Fire Tower, Inside Tower, Dufur, OR:  On or about October 11th, 2017 and at times prior thereto, the employer did not ensure all unused openings on electrical boxes were closed. There were two (2) unused openings on the electrical junction box above the sink.  This exposed employees to an electrical shock of 110 volt, when operating the switch.          The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(1)(ii) which was contained in OSHA inspection number 1055218, notice number 2, item number 2 and was affirmed as a final order on 11/03/2015, with respect to a workplace located at Prairie City Ranger District.    The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(1)(ii) which was contained in OSHA inspection number 903968, notice number 1, item number 2 and was affirmed as a final order on 7/01/2013, with respect to a workplace located at Pine Orchards.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.305 B02 I

Repeat Gravity 5 2 instances 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose  (a) Clackamas Ranger District, Ripplebrook Fire Warehouse, Garage, Estacada, OR: On or about August 29th, 2017 and at times prior thereto, the employer exposed employees to 110 volt electrical shock when employees operate a switch with a broken faceplate.    (b) Hood River Ranger District, Ranger Station, Northwest Corner of Office Cubicles:  On or about October 12th, 2017 and at times prior thereto, the employer did not ensure that a 110 volt outlet was covered, exposing employees to an electrical shock.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(2)(i) which was contained in OSHA inspection number 1055260, notice number 1, item number 1 and was affirmed as abated on 7/9/2015, with respect to a workplace located at Malheur National Forest, Aviation Unit.  The Forest Service was previously cited for a violation of this occupation safety and health standard or its equivalent standard 29 CFR 1910.305(b)(2)(i) which was contained in OSHA inspection number 978154, notice number 2, item number 4, and was affirmed final order on 12/11/2014, with respect to a workplace located at Deschutes National Forest, Bend Pine Administration Site.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.305 G02 III

Repeat Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.  (a) Clackamas Ranger District, Ripplebrook Fire Warehouse, Adjacent to Kitchen, Estacada, OR:  On or about August 29th 2017 and at times prior thereto, the employer did not ensure that the power cord for the ice machine had adequate strain relief to prevent pull being transmitted to the joints or terminal screws.  The Forest Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 1055218, notice number 1, item number 1 and was affirmed as a final order on 11/03/2017, with respect to a workplace located at Prairie City Ranger District.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.157 E02

Repeat 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:        (b) Clackamas Ranger District, Ripplebrook Incident Command Post, Main Command Room, Estacada, OR:  On or about 8/29/2017, and at times prior thereto, employees were exposed to smoke inhalation hazards, in that one portable fire extinguisher in the Incident Command Post was not visually inspected at least monthly.    (c) Barlow Ranger District, Clear Lake Lookout Fire Tower, Inside the Tower, Duruf, OR:  On or about October 11th, 2017 and at times prior thereto, the employer did not ensure that an AMEREX Dry Chemical ABC fire extinguisher had a monthly visual inspection.  Without an operating fire extinguisher, employees are exposed to fire and smoke inhalation hazards, during an emergency.    The Forest Service was previously cited for a repeat violation of this occupational safety and health standard, as contained in OSHA inspection number 1053133, citation number 2, item number 1 and was affirmed as a final order on 07/9/2015, with respect to a workplace located at 431 Patterson Bridge road, John Day, Oregon;    The Forest Service was previously cited for a violation of this occupational safety and health standard, as contained in OSHA inspection number 898098, citation number 1, item number 1 and was affirmed as a final order on 05/15/2013, with respect to a workplace located at Springfield Warehouse Complex Springfield Oregon;     Abatement documentation required for this violation.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

1910.132 D01 I

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1)(i): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). With such hazards present, the employer did not select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment.    (a) Hood River Ranger District, Eques G Stew Timber Sale, Mount Hood Parkdale, OR:  On or about October 12th, 2017 and at times prior thereto, the Forest Service did not evaluate the need for calk-soled boots for Timber Sale Associates.  This could expose employees to slips, trips, and falls without the proper footwear.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check.  (a) Barlow Ranger District, Clear Lake Lookout Fire Tower, Inside the Tower, Dufur, OR:  On or about October 11th, 2017 and at times prior thereto, the employer did not ensure that an AMEREX Dry Chemical ABC fire extinguisher received an annual maintenance check.  Without an operating fire extinguisher, employees are exposed to fire and smoke inhalation hazards during an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B04 II B

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4.  (a) Hood River Ranger District, Ranger Station, Break/Lunchroom, Parkdale, OR:  On or about October 12th, 2017 and at times prior thereto, the employer did not ensure that the total cord and plug connected load would not exceed the maximum ampere rating. The 20 ampere outlet was serving a Sharp 9 amp microwave, a Kenmore 8.5 amp microwave, and a Hamilton Beach 13 amp toaster oven. This overloaded circuit exposed employees to potential fire and smoke inhalation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(j)(1)(i): Fixtures, lamp holders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact.  (a) Zigzag Ranger District, Ranger Station, Recycling/Workout Room, Zigzag, OR:  On or about August 30th, 2017 and at times prior thereto, an energized light socket, missing a bulb at the top of the staircase, was within arm's reach of employees in the vicinity.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View FOREST SERVICE, RIPPLEBROOK FIRE WAREHOUSE's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342613189.