CIRCLEVILLE, OH —
OSHA Inspection: ROBERT FRY & ASSOCIATES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROBERT FRY & ASSOCIATES, INC. in 120 NORTH PICKAWAY STREET, CIRCLEVILLE, OH 43113 (NAICS 238310). OSHA activity number 342617685.
Where did this inspection happen?
- Establishment
- ROBERT FRY & ASSOCIATES, INC.
- Site address
- 120 NORTH PICKAWAY STREET
- City
- CIRCLEVILLE
- State
- OH
- ZIP
- 43113
- Mailing
- 9125 HIGH FREE PIKE, WEST JEFFERSON, OH 43162
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2535.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a. On or about September 7, 2017, at the site located at 120 North Pickaway Street in Circleville, Ohio, an employee climbed the bracing of the Waco scaffold, exposing the employee to a fall hazard of approximately 25 feet.
Recent events (2)
- — I (S) $2535.4
- — Z (S) $3622
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. a. On or about September 7, 2017, at the site located at 120 North Pickaway Street in Circleville, Ohio, an employee was framing the roof of an elevator shaft without any means of fall protection, thereby exposing the employee to a fall hazard of approximately 31 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $5070
More inspections at ROBERT FRY & ASSOCIATES, INC.
GROVEPORT, OH—1984-04-11
ROBERT FRY & ASSOCIATES INC
View ROBERT FRY & ASSOCIATES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342617685.