OSHA Inspection: SYMBOL MATTRESS OF FLORIDA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SYMBOL MATTRESS OF FLORIDA, INC. in 5000 MERCANTILE LANE, KISSIMMEE, FL 34758 (NAICS 337910). OSHA activity number 342642154.

Watch Symbol Mattress OF Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Symbol Mattress OF Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5000 MERCANTILE LANE
City
KISSIMMEE
State
FL
ZIP
34758
Mailing
5000 MERCANTILE LANE, KISSIMMEE, FL 34758
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337910
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.178 P01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $5174.00 · Current $3104.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  a. On or about 09/01/2017, at the job site - employees were exposed to struck-by hazards, in that, the forklift was not removed from service after the horn was found defective and documented in several operators daily check list.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.305 G02 III

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a. On or about 09/01/2017, at the job site - the connection plug of a forklift battery charger was partially separated from the flexible cable, in that, the insulation casing was not covering completely and bare wire was visible.