BURLINGTON, MA —
OSHA Inspection: WILSON SITE DEVELOPMENT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WILSON SITE DEVELOPMENT, LLC in 17 TERRY AVE., BURLINGTON, MA 01803 (NAICS 238910). OSHA activity number 342657814.
Where did this inspection happen?
- Establishment
- WILSON SITE DEVELOPMENT, LLC
- Site address
- 17 TERRY AVE.
- City
- BURLINGTON
- State
- MA
- ZIP
- 01803
- Mailing
- 145 PAGE ST., LUNENBURG, MA 01462
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 H01
- Issued
- Penalty
- Initial $3880.00 · Current $2716.00 Reduced
General-duty citation text
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: Jobsite: The employee, working in the unprotected trench, was not protected from water accumulation.
Recent events (2)
- — I (S) $2716
- — Z (S) $3880
1926.651 K02
- Issued
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. Jobsite: The competent person did not remove employees from the unprotected trench with accumulated water.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1926.652 A01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). Jobsite: The employees, installing a prefab concrete structure and associated pipe, within the six-foot deep trench with accumulated water, were not protected from cave-ins.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238910)
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
COLLINSVILLE, IL—2026-07-14
L W CONTRACTORS, INC.
STAUNTON, VA—2026-07-14
BRIERY BRANCH LAND MANAGEMENT LLC
BEND, OR—2026-07-14
317744769 - K & E EXCAVATING INC
MIDDLETOWN, NY—2026-07-14
MC STEEL, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342657814.