Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EARL'S PLUMBING & HEATING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EARL'S PLUMBING & HEATING, LLC in 1409 UPLAND ST., METAIRIE, LA 70003 (NAICS 238220). OSHA activity number 342667227.

Watch Earl'S Plumbing & Heating, LLC — free Get an email when a new federal OSHA severe-injury report for Earl'S Plumbing & Heating, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1409 UPLAND ST.
City
METAIRIE
State
LA
ZIP
70003
Mailing
5107 W. NAPOLEON AVE., METAIRIE, LA 70003
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
40
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    1409 Upland St., Metairie, LA:  On or about August 16, 2017, the employer allowed employees to utilize an electrical extension cord that was underneath standing water in a trench.  The extension cord was energized by a Honda EU2000i portable generator and was used to power a blower which circulated air inside of the trench.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

1926.651 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation:    1409 Upland St., Metairie, LA:  On or about August 16, 2017, the employer allowed employees to perform work in a excavation where standing water was present without ensuring that protective measures and/or water removal methods were in use.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

1926.651 I01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees.    1409 Upland St., Metairie, LA:  On or about August 16, 2017, the employer allowed employees to work in a trench beneath a building without ensuring that a support system was used under the building to ensure stability of the structure.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:    1409 Upland St., Metairie, LA:  On or about August 16, 2017, the employer allowed employees to perform work in an excavation without ensuring that a daily inspection was conducted by a competent person prior to the start of work and as needed throughout the shift.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

OXYCHEM