Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAT ROOFING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CAT ROOFING LLC in 2265, POCATELLO, ID 83204 (NAICS 236115). OSHA activity number 342691615.

Watch CAT Roofing LLC — free Get an email when a new federal OSHA severe-injury report for CAT Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CAT ROOFING LLC
Site address
2265
City
POCATELLO
State
ID
ZIP
83204
Mailing
3590 MOBILE DRIVE, AMMON, ID 83401
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a)  At the job site: On October 5, 2017 fall protection was not provided for four employees installing shingles on a roof with a pitch 8/12 and working at heights between 12' and 16.5' above the ground.   Note: Abatement certification and documentation ARE required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3803

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  (a) On the roof at the site: On October 5, 2017, the employer did not provide fall hazard training to new employees,  prior to employees being exposed to fall hazards.        Note: Abatement documentation and certification ARE required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2000.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) Ladder on the front of house: On October 5, 2017 the ladder used by employees  to access and exit the roof only extended approximately 8 inches above the roof.    Note: Abatement certification and documentation ARE required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3803

1926.1053 B09

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear:  (a) Ladder on the front of house:  On October 5, 2017 employees had to remove roofing debris from the top of ladder prior to exiting the roof.   Note: Abatement documentation and certification ARE required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342691615.