SPRING, TX —
OSHA Inspection: JOSE CASAREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSE CASAREZ in 21119 I-45 S., SPRING, TX 77388 (NAICS 238130). OSHA activity number 342700168.
Where did this inspection happen?
- Establishment
- JOSE CASAREZ
- Site address
- 21119 I-45 S.
- City
- SPRING
- State
- TX
- ZIP
- 77388
- Mailing
- 502 CRENSHAW RD., PASADENA, TX 77504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $2716.00 · Current $1358.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about October 12, 2017, at the construction site where an employee was exposed to struck by hazards when operating a pneumatic nail gun without wearing eye protection.
Recent events (2)
- — I (S) $1358
- — Z (S) $2716
1926.501 B01
- Issued
- Penalty
- Initial $3803.00 · Current $1902.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about October 12, 2017 at the worksite where employees were exposed to fall hazards of more than 6 feet while working on elevated working surfaces without a fall protection system.
Recent events (2)
- — I (S) $1901.5
- — Z (S) $3803
1926.1052 C12
- Issued
- Penalty
- Initial $2716.00 · Current $1358.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: On or about October 12, 2017 on the construction where employees were exposed to a fall as they were accessing a stairway landing that did not have a guardrail system in place.
Recent events (2)
- — I (S) $1358
- — Z (S) $2716
1926.404 F06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about October 12, 2017, at the construction site where an employee was exposed to an electrical hazard while using an electrical extension cord where the ground prong had detached from the plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.