MEADVILLE, PA —
OSHA Inspection: NUTEC TOOLING SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NUTEC TOOLING SYSTEMS, INC. in 18114 RESEARCH DRIVE, MEADVILLE, PA 16335 (NAICS 332999). OSHA activity number 342700499.
Where did this inspection happen?
- Establishment
- NUTEC TOOLING SYSTEMS, INC.
- Site address
- 18114 RESEARCH DRIVE
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 18114 RESEARCH DRIVE, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 58
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $4527.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts. The wheels of the belt sander and the unused portion of the sanding belt were not guarded to prevent hazards of skin abrasion, in-running nip points, and rotating end shafts. B.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Kalamazoo Industries one-inch bench top belt sander for operations including, but not limited to, deburring parts. The wheels of the belt sander and the unused portion of the sanding belt were not guarded to prevent hazards of skin abrasion, and in-running nip points. C.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock. The band saw was not equipped with an adjustable guard to protect the unused portion of the band saw blade and the blade saw guide wheels. D.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock. The band saw door was not complete in that it did not completely protect the band saw blade on the return side. E.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock. The bottom wheel of the band saw and the band saw blade were not guarded. F.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock. The band saw was not equipped with an adjustable guard to protect the unused portion of the band saw blade and the blade saw guide wheels. G.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock. The band saw door was not complete in that it did not completely protect the band saw blade on the return side. H.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock. The bottom wheel of the band saw and the band saw blade were not guarded.
Recent events (2)
- — I (S) $4526.9
- — Z (S) $6467
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts. The guard for the belt sander's power transmission system belt and pulley system was ineffective in that the front of the guard was open. The belt and pulley system was at least 42-inches above the floor. B.) Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA 16335, band saw area, on or about October 13, 2017 and times prior thereto: Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts. The guard for the belt sander's power transmission system belt and pulley system was ineffective in that the back of the guard was open. The belt and pulley system was at least 42-inches above the floor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A.) Nutec Tooling Systems, Inc., assembly A, on or about October 13, 2017 and times prior thereto: An Amerex carbon dioxide fire extinguisher (M/N: 331, S/N: X-270150) was on the floor and was not mounted to a wall surface. B.) Nutec Tooling Systems, Inc., shipping and receiving area, on or about October 13, 2017 and times prior thereto: A Kidde multi-purpose dry chemical fire extinguisher (M/N: PRO 10 TCM-2, S/N: KL-137498) was located within 6-inches of items stored on the counter in shipping and receiving. The location of the fire extinguisher did not make the fire extinguisher readily accessible.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NUTEC TOOLING SYSTEMS, INC.
MEADVILLE, PA—2017-09-21 00:00:00
NUTEC TOOLING SYSTEMS, INC.
View NUTEC TOOLING SYSTEMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342700499.