PENSACOLA, FL —
OSHA Inspection: BUTLER AUTO RECYCLING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BUTLER AUTO RECYCLING, INC. in 6401 N. PALAFOX ST, PENSACOLA, FL 32503 (NAICS 441310). OSHA activity number 342715307.
Where did this inspection happen?
- Establishment
- BUTLER AUTO RECYCLING, INC.
- Site address
- 6401 N. PALAFOX ST
- City
- PENSACOLA
- State
- FL
- ZIP
- 32503
- Mailing
- 6401 N. PALAFOX ST, PENSACOLA, FL 32503
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 D02 III
- Issued
- Abate by
- Penalty
- Initial $2217.00 · Current $1108.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(iii): Flammable or combustible liquid containers were not in accordance with Table H12: a. On or about October 19, 2017, on the southwest side of bay #5, the employer did not ensure a 250 gallon container being used to store gasoline (Class IB liquid) taken from scrape cars was stored in approved containers, employees were exposed to explosive and fire hazards. b. On or about October 19, 2017, on the south side of the maintenance shed the employer did not ensure two 250 gallon containers being used to store gasoline (Class IB liquid) taken from scrape cars was stored in approved containers, employees were exposed to explosion and fire hazards.
Recent events (2)
- — I (S) $1108
- — Z (S) $2217
1910.106 E06 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a. On or about October 19, 2017, on the southwest side of bay #5, the employer did not ensure the nozzle of a 250 gallon container being used to store gasoline (Class IB liquid) taken from scrape cars was grounded to prevent ignition of flammable vapors, employees were exposed to explosive and fire hazards. b. On or about October 19, 2017, on the south side of the maintenance shed the employer did not ensure the nozzles of the two 250 gallon containers being used to store gasoline (Class IB liquid) taken from scrape cars was grounded to prevent ignition of flammable vapors, employees were exposed to explosion and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B02 II
- Issued
- Penalty
- Initial $2217.00 · Current $1108.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: a. On or about October 19, 2017, on the south side of the maintenance shed,the employer did not ensure six free standing cylinder tanks were protected from accidental contact and/or falling over, exposing employees to explosion hazards.
Recent events (2)
- — I (S) $1108
- — Z (S) $2217
1910.178 L01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about October 19, 2017, the employer did not ensure employees operating forklifts daily had successfully completed training that included a combination of formal instruction, practical training, and evaluation of the operator's performance in the workplace under the supervision of a trainer that has the knowledge, training, and experience to train operators and evaluate their competences, exposing employees to struck-by and crushing hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about October 19, 2017, at Butler Auto Recycling, Inc., throughout the facility,, the employer did not implement and maintain a written hazard communication program, exposing employees to skin, eye, and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about October 19, 2017, throughout the facility, the employer did not inform employees on the hazardous chemicals used in the workplaces, exposing employees to skin, eye, inhalation and fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 441310)
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
BARDSTOWN, KY—2026-07-15
69326 - TOWER AUTOMOTIVE OPERATIONS USA I LLC
BREA, CA—2026-07-15
WORLDPAC
PALM DESERT, CA—2026-07-10
AUTOZONE AUTO PARTS
CHELSEA, ME—2026-07-01
SOULE'S AUTO SUPPLY, INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342715307.