OSHA Inspection: JOLLEY CONCRETE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOLLEY CONCRETE, INC. in 42 JUNIOR AVENUE, DANIELSON, CT 06239 (NAICS 327390). OSHA activity number 342725041.

Watch Jolley Concrete, INC. — free Get an email when a new federal OSHA severe-injury report for Jolley Concrete, INC. is published. One employer, no account, unsubscribe in one click.
Site address
42 JUNIOR AVENUE
City
DANIELSON
State
CT
ZIP
06239
Mailing
42 JUNIOR AVENUE, DANIELSON, CT 06239
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
48
Ownership type
A

10 citations on file for this inspection.

1910.37 B06

Serious Gravity 1 4 instances 10 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $1940.00 Reduced
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  A.  On or about October 25, 2017, Block Plant:  Side-hinged exterior man doors were not provided with illuminated EXIT signs.  Signs affixed to the doors were not illuminated by emergency lighting within the building.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1910.38 B

Serious Gravity 1 1 instance 48 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:  A.  On or about October 25, 2017, Facility-Wide:  The company was in the process of developing an emergency action plan, but it had not been implemented.  Employees had not been notified whether or not they were expected to fight incipient stage fires or evacuate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A06

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2587.00 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not in place and maintained in a legible condition:  A.  On or about October 25, 2017, Block Plant:   1. Clark #4 Model C500 50 LPG, Serial Number 355 842 2528 warning labels had been worn and were illegible.  2. Toyota forklift did not have a data plate to indicate the Model, Serial Number or the vehicle's rated capacity.  Warning labels on the vehicle had been damaged and were illegible.  3. Datsun 6000 data plate and warning labels had been damaged and were illegible.  4. Daewoo D355 data plate had been damaged and was illegible.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1910.178 L01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  A.  On or about October 25, 2017, Block Plant and Yard:  Employees operating powered industrial vehicles had not been provided training or evaluation of their skill.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 5 2 instances 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s):  A.  On or about October 25, 2017, Block Plant:  In the following instances, defective powered industrial equipment was in operation with emergency brakes that slipped and did not hold:  1.  Clark 4 forklift, Model C500 50 LPG, Serial 355 842 2528. 2.  Toyota forklift, no identifiable model or serial number.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 E04 III

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:  A. On or about October 25, 2017, Block Plant:  1.  Clark #4:  The two metal straps to secure the propane tank to the equipment were not closed. 2.  Datsun 6000:  The left strap was not closed to effectively secure the propane tank to the vehicle.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $4398.00 · Current $2199.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.  On or about October 25, 2017, Office, near rest room:  A metal storage cabinet and empty cardboard boxes were stored within the working space in front of a 120V electrical panel, preventing easy access for maintenance or inspection.  Labeling in the panel identified that it powered the second floor office lights, exit and emergency lights, truck lights, first and second floor air handler.
Recent events (2)
  • — I (S) $2199
  • — Z (S) $4398

1910.304 G05

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $4398.00 · Current $2199.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   A.  On or about October 25, 2017, Block Plant, at the back of the block making equipment:  A 31"-diameter metal encased MaxxAir floor fan was not grounded.  Stray current was detected in the metal parts of the fan, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $2199
  • — Z (S) $4398

1910.305 G02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   A.  On or about October 25, 2017, Block Plant, behind block making equipment:  The flexible cordset for the 31" diameter metal-encased floor fan had the insulation pulled from its fitting.  Strain on the cordset damaged the ground wire.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 48 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $3234.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  A.  On or about October 25, 2017, Facility-Wide:  The company had not developed or implemented a hazard communication program, which addressed chemical labeling, safety data sheets and employee training on the hazards to which they were exposed, including silica and propane.