Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXPERT GENERAL CONSTRUCTION CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EXPERT GENERAL CONSTRUCTION CORP. in 782 ADAMS STREET, DORCHESTER, MA 02124 (NAICS 238160). OSHA activity number 342725660.

Watch Expert General Construction Corp. — free Get an email when a new federal OSHA severe-injury report for Expert General Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
782 ADAMS STREET
City
DORCHESTER
State
MA
ZIP
02124
Mailing
14 BROAD STREET APARTMENT 3, BROCKTON, MA 02301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3880.00 · Current $1940.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.    Roof of 782 Adams Street, Dorchester, MA:  Employees were installing rubber membrane roofing material without the use of fall protection exposing them to falls of greater than twenty (20) feet to the concrete and pavement below.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2356.00 · Current $1178.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    Second Floor Hallway Access to Roof of 782 Adams Street, Dorchester, MA: Employees were using a fiberglass extension ladder to access the roof that did not extend above the landing exposing employees to falls of approximately ten (10) feet to the ground below.
Recent events (2)
  • — I (S) $1178
  • — Z (S) $2356

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342725660.