1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALLEN ROOFING & SUPPLY, CO.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALLEN ROOFING & SUPPLY, CO. in LOT 29 CATHERINE COURT, O FALLON, MO 63368 (NAICS 238170). OSHA activity number 342732278.

Watch Allen Roofing & Supply, CO. — free Get an email when a new federal OSHA severe-injury report for Allen Roofing & Supply, CO. is published. One employer, no account, unsubscribe in one click.
Site address
LOT 29 CATHERINE COURT
City
O FALLON
State
MO
ZIP
63368
Mailing
525 OLD STATE ROAD, ELLISVILLE, MO 63021
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
100
Ownership type
A

4 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $0.00 Reduced
29 CFR 1926.451(b)(1)(i):   Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide and the employer could not demonstrate that a wider space was necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).  On 10/24/2017, employees from Allen Roofing & Siding were installing siding on a residential building located on lot 29 Catherine Court in O'Fallon, MO.   An employee was installing siding on the front of the residence while standing on tubular welded frame scaffolding.  The platform the employee was working on was not fully planked.
Recent events (3)
  • — J (S) $0
  • — C (S) $8873
  • — Z (S) $8873

1926.451 E01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $0.00 Reduced
29 CFR 1926.451(e)(1):   When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface were not used.   On 10/24/2017, employees from Allen Roofing & Siding were installing siding on a residential building located on lot 29 Catherine Court in OFallon, MO.   An employee was installing siding on the front of the residence while standing on tubular welded frame scaffolding.  The first row of planking was 39-41 inches above the ground.  The employee did not use portable ladders, hook-on ladders, attachable ladders, ramps, walkways, or similar surface to access the scaffolding.
Recent events (3)
  • — J (S) $0
  • — C (S) $8873
  • — Z (S) $8873

1926.451 F03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(3):   Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  On 10/24/2017, employees from Allen Roofing & Siding were installing siding on a residential building located on lot 29 Catherine Court in OFallon, MO.   An employee was installing siding on the front of the residence while standing on tubular welded frame scaffolding.  The scaffolding had not been inspected for visible defects by a competent person.  The scaffolding was missing cross bracing and not fully planked at the working level.
Recent events (3)
  • — J (S) $0
  • — C (S) $8873
  • — Z (S) $8873

1926.452 C02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $0.00 Reduced
29 CFR 1926.452(c)(2):   Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which secured vertical members together laterally. The cross braces were not of such length as would automatically square and align vertical members so that the erected scaffold is always plumb, level, and square.   On 10/24/2017, employees from Allen Roofing & Siding were installing siding on a residential building located on lot 29 Catherine Court in OFallon, MO.   An employee was installing siding on the front of the residence while standing on tubular welded frame scaffolding.  The scaffolding was not adequately braced by cross, horizontal, or diagonal braces, or combination thereof, which secured vertical members together laterally.
Recent events (3)
  • — J (S) $0
  • — C (S) $8873
  • — Z (S) $8873

View ALLEN ROOFING & SUPPLY, CO.'s full OSHA safety record →