Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JORGE DE LEON DL HOMES EXTERIORS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JORGE DE LEON DL HOMES EXTERIORS, LLC. in 3875 GRANDVIEWMANOR DR, CUMMING, GA 30028 (NAICS 238160). OSHA activity number 342743929.

Watch Jorge DE Leon DL Homes Exteriors, LLC. — free Get an email when a new federal OSHA severe-injury report for Jorge DE Leon DL Homes Exteriors, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3875 GRANDVIEWMANOR DR
City
CUMMING
State
GA
ZIP
30028
Mailing
47 BROWN RD., STOCKBRIDGE, GA 30281
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3259.00 · Current $1955.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  On or about 10/31/17 located at 3875 Grandview Manor Dr., Cumming, GA: Employees were roofing the house that was under construction while on top of the roof approximately 35  foot from the lower level. The employee on the roof was throwing and dropping metal flashing to the ground and the employee below was without a hard hat. The boss nearly hit his employee in the head with a 4 x 4 x 6 metal flashing near miss of being struck in the head without hard hats exposing them to a struck by hazards.
Recent events (2)
  • — I (S) $1955.4
  • — Z (S) $3259

1926.102 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2282.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:   On or about 10/31/17 located at 3875 Grandview Manor Dr., Cumming, GA:  Employees were observed installing roofing shingles on the roof of an house that was under construction while using a pneumatic nail guns without safety glasses.
Recent events (2)
  • — I (S) $2281.8
  • — Z (S) $3803

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2282.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    On or about 10/31/17 located at 3875 Grandview Manor Dr., Cumming, GA: Employee (s) were installing roofing shingles on the house that was under construction while working at the edge, the employer did not ensure that fall protection was used by the employees while exposed to fall hazards of approximately 35- feet from the lower level on the 12/12 pitch roof.
Recent events (2)
  • — I (S) $2281.8
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2282.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   On or about 10/31/17 located at 3875 Grandview Manor Dr., Cumming, GA: Employees were observed and exposed to fall hazards, while roofing a house that was under construction and the employees were using a portable extension ladder to gain access to the roof, and the ladder was only 12- inches above the landing surface on the 2nd roof.
Recent events (2)
  • — I (S) $2281.8
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342743929.