COLORADO SPRINGS, CO —
OSHA Inspection: JOHN SENTER TIRE & SERVICE CENTER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOHN SENTER TIRE & SERVICE CENTER, INC. in 3820 E. PIKES PEAK, COLORADO SPRINGS, CO 80909 (NAICS 811111). OSHA activity number 342760204.
Where did this inspection happen?
- Establishment
- JOHN SENTER TIRE & SERVICE CENTER, INC.
- Site address
- 3820 E. PIKES PEAK
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80909
- Mailing
- 3805 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80917
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): (2) The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition. When wet processes were used, drainage were not maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats were not provided: a) On or about November 8, 2017 and at times prior, employees were exposed to slipping hazards from spilled engine oil on the floor. The oil spill oil was coming from transferring oil from the 5-gallon containers to the 275-gallon container.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1910.106 E09 III
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) On or about November 8, 2017 and at times prior, employees were exposed to fire hazards from several soiled rags that were left in the metal receptacle at the service bay area. The metal container can was not provided with a cover.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) On or about November 8, 2017 and at times prior, employees were required to use a bench grinder with the work rest opening of approximately one inch. The work rest of the bench grinder should have a maximum opening of one eight inch distance from the abrasive wheel.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On or about November 8, 2017 and at times prior, employees were required to use a bench grinder with the tongue guard opening of approximately one inch. The tongue guard of the bench grinder should not exceed a one fourth inch distance from the abrasive wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Abate by
- Penalty
- Initial $406.00 · Current $203.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a. On or about November 8, 2017 and at times prior, employees were exposed to possible entrapment due to exit sign located at the south side of the parts room which was not illuminated by a light source of at least five foot-candles. The exit sign would be difficult to see in the event of an emergency.
Recent events (2)
- — I (O) $203
- — Z (O) $406
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $406.00 · Current $203.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Note: Applies to any extinguishers provided in the workplace. Maintenance check includes an internal examination, except extinguishers with stored pressure: a) On or about November 8, 2017 and at times prior, several portable fire extinguishers located in the shop area were not annually maintained. The portable fire extinguishers had an annual maintenance date of April 2016.
Recent events (2)
- — I (O) $203
- — Z (O) $406
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $406.00 · Current $203.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about November 8, 2017 and at times prior, five electrical outlet boxes were installed on the frame of the storage racks and were not used in accordance to its listing and labeling, in that they were not secured to the wall of the building.
Recent events (2)
- — I (O) $203
- — Z (O) $406
1910.304 F01 IV
- Issued
- Abate by
- Penalty
- Initial $406.00 · Current $203.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a. On or about November 8, 2017 and at times prior, an electrical circuit breaker panel located at the west side of the parts area was blocked with shop tools and equipment. The electrical circuit breaker panel was not readily accessible to the employees.
Recent events (2)
- — I (O) $203
- — Z (O) $406
More inspections in this industry (NAICS 811111)
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
MANASSAS, VA—2026-07-15
VAFMC LLC
NORFOLK, VA—2026-07-15
CITY OF NORFOLK DEPT OF GENERAL SERVICES DIVISION OF FLEET MANAGEMENT
ENOLA, PA—2026-07-15
ENOLA AUTO SALES
LYNCHBURG, TN—2026-07-14
MOORE COUNTY SCHOOLS - BUS GARAGE
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342760204.