WRIGHTSVILLE, PA —
OSHA Inspection: DONSCO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DONSCO, INC. in 124 NORTH FRONT STREET, WRIGHTSVILLE, PA 17368 (NAICS 331511). OSHA activity number 342761483.
Where did this inspection happen?
- Establishment
- DONSCO, INC.
- Site address
- 124 NORTH FRONT STREET
- City
- WRIGHTSVILLE
- State
- PA
- ZIP
- 17368
- Mailing
- P.O. BOX 2001, WRIGHTSVILLE, PA 17368
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 150
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $11086.00 · Current $8315.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) Core Room - The machine specific lockout/tagout procedure for the Redford 22 core machines did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques for the control of hazardous energy in that this procedure did not require employees to utilize lockout/tagout when doing set-up activities, including, but not limited to troubleshooting where employees removed guarding or could reach around guarding, and core box changes, where employees relied on interlock devices (control circuitry), exposing the employees to the hazards of getting caught in, caught by, or struck by moving machine parts, on or about October 30, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $8314.5
- — Z (S) $11086
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) Core Room - The employer did not provide adequate training in lockout/tagout in that the employer did not require employees to use and employees did not use lockout/tagout when doing set-up activities, including, but not limited to troubleshooting, on the Redford 22 core machines, exposing the employees to the hazards of getting caught in, caught by, or struck by moving machine parts, on or about October 30, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Core Room - While troubleshooting mechanical problems with Redford 22 core making machines, set-up employees removed/opened fixed guarding that normally enclosed moving machine parts without applying lockout/tagout, exposing these employees to getting caught in or caught by moving machine parts, as happened on or about October 30, 2017, when an employee put his right hand on top of the moving sand magazine and suffered a fingertip amputation after the vertical clamp closed on the sand magazine when the magazine reached the blow position. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at DONSCO, INC.
WRIGHTSVILLE, PA—2026-05-07
DONSCO, INC.
WRIGHTSVILLE, PA—2026-04-02
DONSCO, INC.
WRIGHTSVILLE, PA—2026-04-02
DONSCO INC
MOUNT JOY, PA—2024-03-13 00:00:00
DONSCO INC.
MOUNT JOY, PA—2024-03-13 00:00:00
DONSCO INC.
View DONSCO, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331511)
CORNWALL, PA—2026-07-01
PRL INDUSTRIES INC
CORNWALL, PA—2026-07-01
PRL INDUSTRIES INC
EASTON, PA—2026-07-01
VICTAULIC COMPANY
HAMBURG, PA—2026-06-18
HAMBURG PLOW WORKS, INC.
EADS, TN—2026-06-17
JACKIE CARROLL
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342761483.