BOULDER, CO —
OSHA Inspection: DIETERICH STANDARD, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIETERICH STANDARD, INC. in 5601 N. 71ST ST., BOULDER, CO 80301 (NAICS 334513). OSHA activity number 342761731.
Where did this inspection happen?
- Establishment
- DIETERICH STANDARD, INC.
- Site address
- 5601 N. 71ST ST.
- City
- BOULDER
- State
- CO
- ZIP
- 80301
- Mailing
- 5601 N. 71ST ST., BOULDER, CO 80301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- Employees
- 107
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $7068.00 · Current $7068.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Dieterich Standard, Inc. at 5601 N. 71st St., Boulder, CO 80301: On and before November 8, 2017, the employer did not ensure that one or more methods of machine guarding was provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks, in the following instances: 1) The Colchester Clausing Model 600 18", serial number MTO191 was not adequately guarded and exposed employees in the area to hazards from ingoing nip points and rotating parts; 2) The HYDMECH Model H-14A horizontal band saw included a non-working part of the blade that was not guarded; 3) The Okuma L470CNC had an opening on the back side approximately 6 inches in diameter for a bar feeder that was not guarded. In addition, the employer did not provide a table to support the bars to prevent the bars (materials) from falling on the operator, and to prevent employees in this area from being impacted by the bars; and 4) The Okuma Multus B300W had an opening on the back side approximately 6 inches in diameter for a bar feeder that was not guarded. In addition, the employer did not provide a table to support the bars to prevent the bars (materials) from falling on the operator, and to prevent employees in this area from being impacted by the bars. These conditions exposed employees using this equipment to amputation, laceration, ingoing nip points, and rotating parts hazards.
Recent events (1)
- — Z (S) $7068
More inspections in this industry (NAICS 334513)
OSSEO, MN—2026-07-08
111550 - CARL ZEISS INDUSTRIAL METROLOGY LLC
BENTON HARBOR, MI—2026-07-07
MIDWEST TIMER SERVICE, INC.
PROVIDENCE, RI—2026-04-21
MAHR INC.
WINSTON SALEM, NC—2026-04-16
161015 - FAIRCHILD INDUSTRIAL PRODUCTS COMPANY
KENT, WA—2026-03-09
WA317990187 - SEATTLE METRICS INC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342761731.