Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXTERIOR CONCEPTS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EXTERIOR CONCEPTS INC. in 11040 TWENTY MILE ROAD, PARKER, CO 80134 (NAICS 238170). OSHA activity number 342782398.

Watch Exterior Concepts INC. — free Get an email when a new federal OSHA severe-injury report for Exterior Concepts INC. is published. One employer, no account, unsubscribe in one click.
Site address
11040 TWENTY MILE ROAD
City
PARKER
State
CO
ZIP
80134
Mailing
4975 LITTLE MILL ROAD, BUFORD, GA 30518
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1500.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):      a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that the scaffold system was fully planked on the third level of the scaffold. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2716

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1500.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:      a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that a ladder system was provided for the workers to access and egress the upper levels of the scaffold system. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2716

1926.451 G04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1500.00 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:      a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that guardrail systems were installed along all open sides of the scaffold system. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2716

1926.451 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:   a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that a competent person inspected the scaffold for visible defects before each work shift. The scaffold system was not fully planked on the third level, a ladder system was not provided for the employees to access and egress the upper levels of the scaffold system; and guardrail systems were not installed along all open sides of the platform. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:   a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that the scaffold was erected or altered by trained and experienced employees. The scaffold system was not fully planked on the third level, a ladder system was not provided for the employees to access and egress the upper levels of the scaffold system; and guardrail systems were not installed along all open sides of the platform. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:   a) On or about November 15, 2017 and at times prior, Exterior Concepts, Inc., as the controlling employer, did not ensure that the workers on the job site were trained by a qualified person to recognize the hazards associated with the scaffold system. The scaffold system was not fully planked on the third level, a ladder system was not provided for the employees to access and egress the upper levels of the scaffold system; and guardrail systems were not installed along all open sides of the platform. Workers of Fernando Garces Marin were working on a scaffold system and exposed to fall hazards of approximately 21 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View EXTERIOR CONCEPTS INC.'s full OSHA safety record →