Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROBERTO PEREZ

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROBERTO PEREZ in 163 ALTAMA CONNECTOR, BRUNSWICK, GA 31525 (NAICS 238140). OSHA activity number 342789773.

Watch Roberto Perez — free Get an email when a new federal OSHA severe-injury report for Roberto Perez is published. One employer, no account, unsubscribe in one click.
Establishment
ROBERTO PEREZ
Site address
163 ALTAMA CONNECTOR
City
BRUNSWICK
State
GA
ZIP
31525
Mailing
2597 CANDLER WAY, MARIETTA, GA 30060
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  (a) Around the exterior of the building, on or about and at times preceding to November 17, 2017, employees were installing stucco from the tubular welded scaffold without the working platforms being fully planked, exposing employees to a fall hazard.
Recent events (1)
  • — Z (S) $3880

1926.451 E01

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $2772.00
29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform more than 2 feet above or below a point of access:  (a) Around the exterior of the building, on or about and at times preceding to November 17, 2017, employees were installing stucco from the tubular welded scaffold without the use of access ladders, exposed to a 12 foot fall hazard.
Recent events (1)
  • — Z (S) $2772

1926.451 G01 VII

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  (a) Around the exterior of the building, on or about and at times preceding to November 17, 2017, employees were installing stucco from the tubular welded scaffold without the use of fall protection, exposed to a 12 foot fall hazard.
Recent events (1)
  • — Z (S) $3880

View ROBERTO PEREZ's full OSHA safety record →