STATE COLLEGE, PA —
OSHA Inspection: POLYMICS LTD.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of POLYMICS LTD. in 2215 HIGH TECH ROAD, STATE COLLEGE, PA 16803 (NAICS 326199). OSHA activity number 342798527.
Where did this inspection happen?
- Establishment
- POLYMICS LTD.
- Site address
- 2215 HIGH TECH ROAD
- City
- STATE COLLEGE
- State
- PA
- ZIP
- 16803
- Mailing
- 2215 HIGH TECH ROAD, STATE COLLEGE, PA 16803
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7760.00 · Current $5432.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard from flying polyvinyl chloride (PVC) pipe fragments: (a) Polymics, LTD, 2215 High Tech Road, State College, PA 16803 - The employer used schedule 80 polyvinyl chloride (PVC) piping of varying diameters to transport compressed air to pneumatically powered equipment and machinery, exposing employees to a struck-by hazard from flying PVC pipe fragments associated with such use of PVC piping in above ground installations. According to the Plastic Pipe Institute and the Plastic Pipe and Fittings Association, PVC piping does not possess shatter resistant properties, and failure of the piping presents a serious hazard to employees from resultant flying shards or pipe fragments which become rapidly propelled by the released energy of a suddenly decompressing gas, ASME B31.3, A323.4.2 states PVC and CPVC shall not be used in compressed air or other compressed gas service, or ASME B31.9 paragraph 923.3.2 states PVC, CPVC and PVDF, which exhibit brittle failures as determined by ASTM F412, shall not be used for compressed air or gas service, on or about November 14th, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $5432
- — Z (S) $7760
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $4527.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed to ensure that lockout devices were under the exclusive control of the authorized employee performing the servicing or maintenance: a) Lock-out/Tag-out Program - Employees performing lock-out/tag-out procedures were exposed to possible stored energy from the availability of extra keys and alternate keys in the Maintenance toolbox, on or about November 14th, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $4526.9
- — Z (S) $6467
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Lock-out/Tag-out - The employer did not perform a complete annual review of the lockout/tagout program, on or about November 14th, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) Fire Extinguishers - Fire extinguishers were not inspected on a monthly basis exposing employees to possible fire hazards, on or about November 14th, 2017. Note: Applies to any extinguishers provided in the workplace. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at POLYMICS LTD.
STATE COLLEGE, PA—2011-08-22 00:00:00
POLYMICS, LTD.
View POLYMICS LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source