Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POLYMICS LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POLYMICS LTD. in 2215 HIGH TECH ROAD, STATE COLLEGE, PA 16803 (NAICS 326199). OSHA activity number 342798527.

Watch Polymics LTD. — free Get an email when a new federal OSHA severe-injury report for Polymics LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
POLYMICS LTD.
Site address
2215 HIGH TECH ROAD
City
STATE COLLEGE
State
PA
ZIP
16803
Mailing
2215 HIGH TECH ROAD, STATE COLLEGE, PA 16803
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
50
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $7760.00 · Current $5432.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by hazard from flying polyvinyl chloride (PVC) pipe fragments:   (a) Polymics, LTD, 2215 High Tech Road, State College, PA 16803 - The employer used schedule 80 polyvinyl chloride (PVC) piping of varying diameters to transport compressed air to pneumatically powered equipment and machinery, exposing employees to a struck-by hazard from flying PVC pipe fragments associated with such use of PVC piping in above ground installations. According to the Plastic Pipe Institute and the Plastic Pipe and Fittings Association, PVC piping does not possess shatter resistant properties, and failure of the piping presents a serious hazard to employees from resultant flying shards or pipe fragments which become rapidly propelled by the released energy of a suddenly decompressing gas, ASME B31.3, A323.4.2 states PVC and CPVC shall not be used in compressed air or other compressed gas service, or ASME B31.9 paragraph 923.3.2 states PVC, CPVC and PVDF, which exhibit brittle failures as determined by ASTM F412, shall not be used for compressed air or gas service, on or about November 14th, 2017.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $5432
  • — Z (S) $7760

1910.147 C04 I

Serious Gravity 5 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $4527.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed to ensure that lockout devices  were under the exclusive control of the authorized employee performing the servicing or maintenance:  a) Lock-out/Tag-out Program - Employees performing lock-out/tag-out procedures were exposed to possible stored energy from the availability of extra keys and alternate keys in the Maintenance toolbox, on or about November 14th, 2017.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $4526.9
  • — Z (S) $6467

1910.147 C06 I

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Lock-out/Tag-out - The employer did not perform a complete annual review of the lockout/tagout program, on or about November 14th, 2017.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a) Fire Extinguishers - Fire extinguishers were not inspected on a monthly basis exposing employees to possible fire hazards, on or about November 14th, 2017.  Note: Applies to any extinguishers provided in the workplace.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View POLYMICS LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342798527.