WELLESLEY, MA —
OSHA Inspection: THE WIESE COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE WIESE COMPANY in 8 FALMOUTH ROAD, WELLESLEY, MA 02481 (NAICS 236118). OSHA activity number 342806841.
Where did this inspection happen?
- Establishment
- THE WIESE COMPANY
- Site address
- 8 FALMOUTH ROAD
- City
- WELLESLEY
- State
- MA
- ZIP
- 02481
- Mailing
- 28 NORTH MAIN STREET, SHERBORN, MA 01770
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 11
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.300 B04 II
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $3042.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: Location: Tables saws at the front and rear of the building. Table saw blades were unguarded at the point of operation.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.404 F06
- Issued
- Penalty
- Initial $3622.00 · Current $2173.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: Extension cords powered by Subaru Powermate generator at the rear of the house. Two extension cords, one yellow and one green, lacked ground prongs.
Recent events (2)
- — I (S) $2173
- — Z (S) $3622
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $3042.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Jobsite: Scaffolds at rear of building. The carpenters bracket scaffold at the rear of the building was not fully planked.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.451 F01
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2173.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(1): Scaffold and/or scaffold components were loaded in excess of their maximum intended loads or rated capacities, whichever was less: Location: rear of house The pump jack scaffold work platform was loaded in excess of its 250 pound rated load.
Recent events (2)
- — I (S) $2173
- — Z (S) $3622
1926.451 G01
- Issued
- Penalty
- Initial $5070.00 · Current $3042.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. Jobsite: Rear of building Instance A: Employees on a pump jack scaffold who's work platform was approximately 21feet high were not adequately protected against the fall hazard. Instance B: Employees on a carpenters bracket scaffold was not adequately protected against a fall hazard of approximately 19.5 feet.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Jobsite: An employee had not been adequately trained in scaffold hazards and the control of those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2173.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Location: Pump jack scaffold at rear of building. A pump jack scaffold was only secured to the structure at it's top. The scaffold poles were approximately 30 feet long.
Recent events (2)
- — I (S) $2173
- — Z (S) $3622
1926.1052 C01 II
- Issued
- Penalty
- Initial $2897.00 · Current $1738.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: Location: Rear of Building The stairs used to access the first floor lacked a stair rail system on either side.
Recent events (2)
- — I (S) $1738
- — Z (S) $2897
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $3042.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Jobsite: pump jack scaffold at rear of building. A metal extension ladder used to access a scaffold work platform did not extend at least 3 feet above the upper surface of the platform. An employees descending the ladder was seriously injured when he fell from the ladder which slipped off the work platform.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.403 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Location: Rear of building. Instance A: The power tap used to power the table and miter saws was listed for indoor use only. Instance B: Extension cords were 'daisy chained'.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236118)
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
VANCOUVER, WA—2026-07-08
WA317991978 - DLS CONTRACTING INC
NEWPORT BEACH, CA—2026-07-08
DRAKE SMITH CONSTRUCTION
BRIDGEVILLE, PA—2026-07-08
EXTREME DECKS
COLUMBUS, OH—2026-07-07
QUALITY BUILDS OHIO LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342806841.