Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE COGUAHO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE COGUAHO in 1205 JEFFERSON AVE., NAPERVILLE, IL 60540 (NAICS 238160). OSHA activity number 342814811.

Watch Jose Coguaho — free Get an email when a new federal OSHA severe-injury report for Jose Coguaho is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE COGUAHO
Site address
1205 JEFFERSON AVE.
City
NAPERVILLE
State
IL
ZIP
60540
Mailing
3337 W. CULLOM AVE., CHICAGO, IL 60618
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $311.00 · Current $311.00
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.     Jose Coguaho, dba Jose Coguaho, failed to submit documents to OSHA verifying that each of the following cited violations had been corrected:     Citation Number                     Item Number                          Abatement Date  1                                                       3a                                     2/9/2018  1                                              3b                                     2/9/2018 1                                              3c                                     2/9/2018   In accordance with 29 CFR 1903.19(d), abatement documentation is required for this violation.
Recent events (1)
  • — Z (O) $311

1926.100 A

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2217.00 · Current $2217.00
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  On or about December 5, 2017, at the above referenced worksite, employees performing residential roofing installation on a single family residential property were exposed to struck by hazards where employees worked on two different levels, and the employer failed to mandate the use of hard hats.    No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $2217

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.   On or about December 5, 2017, at the above referenced worksite, employees performing roofing installation operations on the roof at a single family property were exposed to falls of approximately 8.1 feet and 18 feet, when the employer failed to ensure that fall protection was utilized.   No abatement certification or documentation is required of this item.
Recent events (1)
  • — Z (S) $3880

1926.1051 A

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.  On or about December 5, 2017, at the above referenced worksite, employees engaged in roofing installation on a single-family residential property were exposed to fall hazards of approximately 8.1 feet and 18 feet, when the employer failed to ensure a dedicated ladder was in place for access between three separate work areas.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $3880

1926.1053 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about December 5, 2017, at the above referenced worksite, employees engaged in roofing installation on a single-family residential property were exposed to fall hazards of approximately 8.1 feet and 18 feet, when the employer failed to ensure the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.  On or about December 5, 2017, at the above referenced worksite, employees engaged in roofing installation on a single-family residential property were exposed to fall hazards of approximately 8.1 feet and 18 feet, when the employer failed to ensure a ladder was used in the purpose in which it was designed.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342814811.