2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WIREGRASS GIN COMPANY, L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WIREGRASS GIN COMPANY, L.L.C. in WEST COOK RD ATTN: ALLEN BARRENTINE, DOTHAN, AL 36301 (NAICS 115111). OSHA activity number 342824877.

Watch Wiregrass GIN Company, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Wiregrass GIN Company, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
WEST COOK RD ATTN: ALLEN BARRENTINE
City
DOTHAN
State
AL
ZIP
36301
Mailing
905 WEST COOK RD, DOTHAN, AL 36301
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115111
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.147 F03 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $0.00 Reduced
29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4):  a) On or about November 28, 2017 and times prior at the 2B lint cleaner: The employer failed to ensure group lockout was conducted for the 2B lint cleaner when an employee entered the rear of the machine to clear a clog resulting in finger amputations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

1928.57 D01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $5174.00
29 CFR 1928.57(d)(1)(i):     The main drive and miscellaneous drives of gin stands shall be completely enclosed, guarded by location, or guarded by railings (consistent with the requirements of paragraph (a)(7) of this section). Drives between gin stands shall be guarded so as to prevent access to the area between machines.
Recent events (2)
  • — I (S) $5174
  • — Z (S) $5174

1910.219 D01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $0.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a) On or about November 28, 2017 and times prior at the 2B lint cleaner: The employer failed to ensure the belt and pulley for the lint saw blade drum was guarded to prevent inadvertent contact as an employee walked past it while entering the rear of the machine to clear a clog.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342824877.