Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TOKOS ELECTRIC INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TOKOS ELECTRIC INC. in COURT & HAWLEY STREETS, BINGHAMTON, NY 13901 (NAICS 238210). OSHA activity number 342825239.

Watch Tokos Electric INC. — free Get an email when a new federal OSHA severe-injury report for Tokos Electric INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TOKOS ELECTRIC INC.
Site address
COURT & HAWLEY STREETS
City
BINGHAMTON
State
NY
ZIP
13901
Mailing
40 TOKOS ROAD, BINGHAMTON, NY 13905
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 10 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3881.00 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures:  a)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts on the 3rd floor service panel where the cover was not installed.   b)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts on the 3rd floor old service panel where there was no cover.    c)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts on the 2nd floor old service panel where there was no cover.   d)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts in the street side stairwell where the temporary lighting wiring was exposed.    e)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts in the parking lot side stairwell where the temporary lighting wiring was exposed.
Recent events (2)
  • — I (S) $3880.5
  • — Z (S) $5174

1926.1053 B13

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a)  At the jobsite, on or about 11/17/17:  A worker was on the top levels of an 8 foot step ladder, straddling the top and standing on the outer supports.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.59

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.59:  An employer engaged in construction activities did not comply with the requirements set forth in Part 1910, Section 1200, Hazard Communication:  a)  At the jobsite, on or about 11/17/17:  Employees were working with chemicals on the jobsite without a HAZCOM program, subsequent training, direction on use of PPE, or availability of SDS's.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.403 B02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a)  At the jobsite, on or about 11/17/17:  Employees were using an extension cord that was hard wired into a service panel, and where that power source was not GFI protected.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.403 I02 II

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(i)(2)(ii): In locations where electric equipment operating at 600 volts, nominal, or less is exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:  a)  At the jobsite, on or about 11/17/17:  Employees were exposed to live electrical parts on the 1st floor new service panels where a temporary foamcore/plastic cover was installed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342825239.