Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHIVERELLA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHIVERELLA, INC. in 479 SOUTH MOUNTAIN BLVD, MOUNTAIN TOP, PA 18707 (NAICS 811111). OSHA activity number 342831849.

Watch Chiverella, INC. — free Get an email when a new federal OSHA severe-injury report for Chiverella, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CHIVERELLA, INC.
Site address
479 SOUTH MOUNTAIN BLVD
City
MOUNTAIN TOP
State
PA
ZIP
18707
Mailing
479 SOUTH MOUNTAIN BLVD, MOUNTAIN TOP, PA 18707
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
90
Ownership type
A

3 citations on file for this inspection.

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    a) Auto Garage/Service Bay - Employees used the circuit breaker in an electrical panel on a daily basis to operate fluorescent lighting with an unused opening (missing blank) in the electrical panel exposing the employees to electrical shock or arc hazards, as observed on or about December 13, 2017.                  IN ACCORDANCE WITH 1903.19, ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  a) Auto Garage/Service Bay- Employees used unlabeled circuit breakers in an electrical panel on a daily basis to operate fluorescent lights exposing the employees to electric shock or arc hazards, as observed on or about December 13, 2017.                        IN ACCORDANCE WITH 1903.19, ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information:   a) At the facility: Employees worked with hazardous chemicals, including, but not limited to, Pride Universal concentrated antifreeze/coolant which includes ethylene glycol, and the employer did not provide these employees with the required training on the new label elements and safety data sheet format as required by the revised OSHA Hazard Communication Standard incorporating the Globally Harmonized System of Classification and Labeling of Chemicals prior to the effective date of December 1, 2013, as observed on or about December 13, 2018.                                                            ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342831849.