Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE TRI-MAR MANUFACTURING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE TRI-MAR MANUFACTURING COMPANY in 191 CAPTAIN LEWIS DRIVE, SOUTHINGTON, CT 06489 (NAICS 332710). OSHA activity number 342861382.

Watch THE Tri-Mar Manufacturing Company — free Get an email when a new federal OSHA severe-injury report for THE Tri-Mar Manufacturing Company is published. One employer, no account, unsubscribe in one click.
Site address
191 CAPTAIN LEWIS DRIVE
City
SOUTHINGTON
State
CT
ZIP
06489
Mailing
191 CAPTAIN LEWIS DRIVE, SOUTHINGTON, CT 06489
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
11
Ownership type
A

6 citations on file for this inspection.

1910.133 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2956.00 · Current $1478.00 Reduced
29 CFR 1910.133(a)(3): The employer did not ensure that employees wearing prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design or wears eye protection that can be worn over the prescription lenses:   Shop:  On, or about, January 3, 2018, an employee was operating an Okuma LB300EX II turning center and using compressed air for cleaning without wearing safety glasses with side shields.
Recent events (2)
  • — I (S) $1478
  • — Z (S) $2956

1910.242 B

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   Shop:  On, or about, January 3, 2018, compressed air nozzles provided at the following machines were measured to be greater than 30 p.s.i., dead-ended:  A.  Okuma MU-400V II:  80 p.s.i.    B.  Okuma LB300EX II:  >100 p.s.i.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 7 instances 8 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $1848.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Shop:  On, or about, January 3, 2018, on the following machines, door interlocks had been bypassed:    A.  Okuma MU-500VA. B.  Tsugami FMA3-II.  The tool changer cover interlock had also been bypassed.   C.  Hitachi Seiki lathe.   D.  Okuma MU-400V II.  Also, the panel/door provided for the tool changer area was removed from the machine.   E.  Turning Area, Okuma LB300EX II. F.  Turning Area, Okuma Space Turn LB3000EX. G.  Turning Area, Okama Space Turn LB3000EX.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3696

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Welding Area:  On, or about, January 3, 2018, the tongue guard provided on the right side of the Craftsman bench grinder was adjusted approximately .58 inch from the wheel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Shop, Near Office Door:  On, or about, January 3, 2018, bar stock and egg cartons were stored on the floor under and in front of the Westingthouse panelboard and Panel C, a circuit breaker panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Welding Area:  On, or about, January 3, 2018, the outlet that energized the Craftsman bench grinder, model 397.195B1, was not provided with a cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342861382.