Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PAYCO BUILDING SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PAYCO BUILDING SUPPLY in 3146 FULLING MILL ROAD, MIDDLETOWN, PA 17057 (NAICS 444190). OSHA activity number 342861390.

Watch Payco Building Supply — free Get an email when a new federal OSHA severe-injury report for Payco Building Supply is published. One employer, no account, unsubscribe in one click.
Site address
3146 FULLING MILL ROAD
City
MIDDLETOWN
State
PA
ZIP
17057
Mailing
3146 FULLING MILL ROAD, MIDDLETOWN, PA 17057
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
17
Ownership type
A

6 citations on file for this inspection.

1910.28 B02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3141.00 · Current $2038.00 Reduced
29 CFR 1910.28(b)(2)(ii): The employer did not ensure that when any portion of a guardrail system, gate, or chains was removed, and an employee must lean through or over the edge of the access opening to facilitate hoisting, employees were protected from falling by a personal fall arrest system:    a) Upper mezzanine - Employees working on the mezzanine did not wear personal fall arrest systems during hoisting operations while the guardrail was removed exposing employees to unprotected side or edges of approximately 12 feet to the ground below, on or before January 4, 2018.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
  • — I (S) $2037.5
  • — Z (S) $3141

1910.213 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3141.00 · Current $2038.00 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a) 3146 Fulling Mill Road -  A Ryobi model number RTS30 10 inch 15 amp table saw blade was not guarded, on or before January 4, 2018.    b) 3146 Fulling Mill Road -  A Ryobi model number Ryobi RTS10G 10 inch 15 amp table saw blade was not guarded, on or before January 4, 2018.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2037.5
  • — Z (S) $3141

1910.213 C02

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  a) 3146 Fulling Mill Road -  A Ryobi model number RTS30 10 inch 15 amp table saw did not have a spreader attached to keep the wood from pinching, on or before January 4, 2018.    b) 3146 Fulling Mill Road -  A Ryobi model number Ryobi RTS10G 10 inch 15 amp table saw did not have a spreader attached to keep the wood from pinching, on or before January 4, 2018.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:   a) 3146 Fulling Mill Road -  A Ryobi model number RTS30 10 inch 15 amp table saw blade did not have non kickback fingers installed, on or before January 4, 2018.    b) 3146 Fulling Mill Road -  A Ryobi model number Ryobi RTS10G 10 inch 15 amp table saw blade did not have non kick fingers installed, on or before January 4, 2018.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1885.00 · Current $1225.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      b) 3146 Fulling Mill Road - A 30 inch Air Circulating fan model 30ACHOA power cord was missing its grounding pin, on or before January 4th 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.    ___________________________Instance A deleted per ISA_______________________________      a) 3146 Fulling Mill Road - A Makita model number LS 1040 power cord was missing its grounding pin, on or before January 4th 2018.
Recent events (2)
  • — I (S) $1225
  • — Z (S) $1885

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1885.00 · Current $1225.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    a) 3146 Fulling Mill Road - A Makita model number LS 1040 power cord was pulled away from the strain relief device located on the saw exposing employees to electrical shock hazards, on or before January 4, 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1225
  • — Z (S) $1885

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342861390.