CINCINNATI, OH —
OSHA Inspection: CHRIS KOCH
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHRIS KOCH in 12113 MOSTELLER RD, CINCINNATI, OH 45241 (NAICS 238160). OSHA activity number 342870805.
Where did this inspection happen?
- Establishment
- CHRIS KOCH
- Site address
- 12113 MOSTELLER RD
- City
- CINCINNATI
- State
- OH
- ZIP
- 45241
- Mailing
- 2574 SHAWHAN RD., LEBANON, OH 45036
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). On January 10, 2018, located on the north side of a commercial exterior structure, employees were exposed to an electrical hazard while installing 2 X 4 lumber onto a steep roof while operating a JLG Articulating Boom Lift within 10 feet of 480 volt electrical line. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1000
- — Z (S) $3880
1926.453 B02 V
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). On January 10, 2018, located on the north side of a commercial exterior structure, employees were exposed to a fall hazard while standing inside a JLG Articulating Boom Lift basket Model# 450AJ installing 2 X 4 lumber onto a steep commercial pitch roof without a lanyard being attached to the boom or basket. Potential fall height was measured to be 23'-9". In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a) On January 9, 2018, located on the north side of a commercial exterior structure, an employee was observed working on a steep pitch roof ridge while wearing a harness that was not attached to an already installed temper anchor with rope and rope grab. Potential Fall Heights were measured to be 23'-9" with a roof pitch of 8/12. b) On January 10, 2018, located on the north side of a commercial exterior structure, employees were observed installing temper anchors to a steep pitch roof ridge while wearing a harness that was not attached to an already installed temper anchor with rope and rope grab. Potential Fall Heights were measured to be 23'-9" with a roof pitch of 8/12. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1926.1053 B12
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.951(c)(1) of this part. a) On January 9, 2018, located on the north side of a commercial exterior structure, employees were utilizing a Werner 32' aluminum extension ladder with conductive side rails to gain access to a steep commercial pitch roof located within 480 volts of an energized electrical power line. b) On January 10, 2018, located on the north side of a commercial exterior structure, employees were utilizing a Werner 32' aluminum extension ladder with conductive side rails to gain access to a steep commercial pitch roof located within 480 volts of an energized electrical power line. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342870805.