Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SENECA BUILDING COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SENECA BUILDING COMPANY, INC. in 2787 LYONS ROAD, GENEVA, NY 14456 (NAICS 238130). OSHA activity number 342895513.

Watch Seneca Building Company, INC. — free Get an email when a new federal OSHA severe-injury report for Seneca Building Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2787 LYONS ROAD
City
GENEVA
State
NY
ZIP
14456
Mailing
323 JAY STREET, GENEVA, NY 14456
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2772.00 · Current $2079.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards due to a collapsing structure:     a) On or about 1/23/2018, 2787 Lyons Road, at the construction site: Employees were working underneath a roof structure consisting of wooden trusses, wooden purlins and metal sheathing.  The roof structure was not adequately secured to the walls of the structure to prevent uplift.      Among other methods, feasible and acceptable abatement methods to correct the hazard is to:         1) Install Screwed connections, metal anchors, metal ties or metal straps between the truss's and the top plate of the wall per  Building Component Safety Information (BCSI) pg 68, as referenced in the truss erections sheets provided at the time of delivery.        2) Utilize A Registered Building Designer to determine bracing and load transfer elements as is referenced in Building Component Safety Information (BCSI) pg 3 and pg 32.          3) Install anchorage from the roof to the walls to resist uplift forces as referenced in section 1604.8 of the International Building Code adopted by New York State.
Recent events (2)
  • — I (S) $2079
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342895513.