GENEVA, NY —
OSHA Inspection: SENECA BUILDING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SENECA BUILDING COMPANY, INC. in 2787 LYONS ROAD, GENEVA, NY 14456 (NAICS 238130). OSHA activity number 342895513.
Where did this inspection happen?
- Establishment
- SENECA BUILDING COMPANY, INC.
- Site address
- 2787 LYONS ROAD
- City
- GENEVA
- State
- NY
- ZIP
- 14456
- Mailing
- 323 JAY STREET, GENEVA, NY 14456
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $2772.00 · Current $2079.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards due to a collapsing structure: a) On or about 1/23/2018, 2787 Lyons Road, at the construction site: Employees were working underneath a roof structure consisting of wooden trusses, wooden purlins and metal sheathing. The roof structure was not adequately secured to the walls of the structure to prevent uplift. Among other methods, feasible and acceptable abatement methods to correct the hazard is to: 1) Install Screwed connections, metal anchors, metal ties or metal straps between the truss's and the top plate of the wall per Building Component Safety Information (BCSI) pg 68, as referenced in the truss erections sheets provided at the time of delivery. 2) Utilize A Registered Building Designer to determine bracing and load transfer elements as is referenced in Building Component Safety Information (BCSI) pg 3 and pg 32. 3) Install anchorage from the roof to the walls to resist uplift forces as referenced in section 1604.8 of the International Building Code adopted by New York State.
Recent events (2)
- — I (S) $2079
- — Z (S) $2772
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342895513.