Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTRAL MONITORING AND DISPATCH

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CENTRAL MONITORING AND DISPATCH in 111 GRANDVIEWAVE REAR OFFICE, PITTSBURGH, PA 15211 (NAICS 561621). OSHA activity number 342902400.

Watch Central Monitoring AND Dispatch — free Get an email when a new federal OSHA severe-injury report for Central Monitoring AND Dispatch is published. One employer, no account, unsubscribe in one click.
Site address
111 GRANDVIEWAVE REAR OFFICE
City
PITTSBURGH
State
PA
ZIP
15211
Mailing
111 GRANDVIEW AVENUE, PITTSBURGH, PA 15211
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561621
Employees
15
Ownership type
A

11 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 2 instances 9 exposed
Issued
Penalty
Initial $3141.00 · Current $1571.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    a)  In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The center door through the utility closet which accessed the outside hallway emergency exit leading to the rear of the office space was not marked "Exit".    b) In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The main door and secondary door to the dispatch office were not marked with "Exit" signs.
Recent events (3)
  • — F (S) $1571
  • — C (S) $3141
  • — Z (S) $3141

1910.37 B05

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or identified by a sign indicating its actual use (e.g., closet):  a)  In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The sliding glass door was not marked "Not an Exit".
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.141 A03 I

Serious Gravity 5 6 instances 9 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $1850.00 Reduced
29 CFR 1910.141(a)(3)(i): All places of employment were not kept clean to the extent that the nature of the work allowed:      a)  In the Main Dispatch Room, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - Employees were surrounded by telephone wires and equipment on the desk.  The desks were dusty and dirty. The floor was dirty, dusty (with ashes/ butts and paper) and cluttered with boxes.      b)  Near the main door and secondary door to the dispatch office, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The floor and table top was covered with cigarette butts/ashes and other dirt debris.    c) In the Side Office Space, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The room and floor was cluttered with boxes, decorations, files, dirt and debris.    d) In the Bathroom, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The bathroom walls were coated with black/grey soot.    e)  In the Kitchen, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The kitchen counter areas were cluttered and bags of garbage & boxes were on the floor.     f)  In the Communication Center Area, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - Telephone wires and various sizes of equipment was stored throughout the space and on the floor presenting excessive clutter.
Recent events (3)
  • — F (S) $1850
  • — C (S) $3696
  • — Z (S) $3696

1910.141 A05

Deleted Serious Gravity 1 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(a)(5):  Every enclosed workplace was not so constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects, and other vermin:  a) In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - Employees were allowed to smoke in the vestibule area and propped the outside door open allowing insects and rodents to enter through the door opening.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.141 D02 II

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(ii): Each lavatory was not provided with hot and cold running water, or tepid running water:  a) In the Bathroom, 111 Grandview Pittsburgh PA, On or about January 25, 2018 - The hot water faucet did not work where hot or tepid water was not available for hand washing.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 2 instances 9 exposed
Issued
Penalty
Initial $3141.00 · Current $1571.00 Reduced
29 CFR 1910.157(c)(1): The employer provided portable fire extinguishers that were not mounted, located and identified so that they are readily accessible to employees without subjecting the employees to possible injury:    a) In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The fire extinguishers were not located and identified in set locations.    b) In the Main Dispatch Area, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - A fire extinguisher was blocked by boxes preventing ready accessibility.
Recent events (3)
  • — F (S) $1571
  • — C (S) $3141
  • — Z (S) $3141

1910.157 G01

Serious Gravity 5 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(g)(1): Where the employer provided portable fire extinguishers for employee use in the workplace, the employer did not also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a) In the Workstation, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - Employees have not been trained in the proper principles and usage of portable fire extinguishers.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 A02 IX

Serious Gravity 1 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1108.00 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard:    a) In the Telecommunication Area, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - Panels of fluorescent light fixtures along the wall were located 73.5 inches from the shop floor were not guarded. There was limited access to permit ready and safe operation and maintenance of the equipment.  Employees accessed telephone wires and equipment near the fluorescent light fixtures.
Recent events (3)
  • — F (S) $1108
  • — C (S) $2217
  • — Z (S) $2217

1910.303 E01 II

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(e)(1)(ii): Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary on the equipment:  a) In the Utility Closet, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - The electrical panel was not marked with the voltage and/or current wattage.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.303 B07

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7): The electric equipment was not installed in a neat and workman like manner:  a) In the Telecommunication Area, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - There was limited access to permit ready and safe operation and maintenance of the equipment due to the following: telephone wires and various size equipment located in the rear space where the ceiling panels were removed and webs of various wires were exposed.  Panels of fluorescent light fixtures along the wall were not covered and open for accidental contact.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.304 B02

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:  a) In the Kitchen, 111 Grandview Ave Pittsburgh PA, On or about January 25, 2018 - A toaster oven, microwave, coffee pot, double toaster were plugged into a surge protector (SurgeMaster II).  The ground fault protector light was not lit therefore the GFCI protection could not be verified.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342902400.