OSHA Inspection: DIANAL AMERICA INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DIANAL AMERICA INC in 9675 BAYPORT BLVD, PASADENA, TX 77507 (NAICS 325211). OSHA activity number 342957941.

Watch Dianal America INC — free Get an email when a new federal OSHA severe-injury report for Dianal America INC is published. One employer, no account, unsubscribe in one click.
Establishment
DIANAL AMERICA INC
Site address
9675 BAYPORT BLVD
City
PASADENA
State
TX
ZIP
77507
Mailing
1999 BRYAN ST STE 900, DALLAS, TX 75201
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
50
Ownership type
A

6 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $12934.00
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.    (a) Dianal America Inc facility: On February 12 2018 and at times prior to, the employer did not document that the facility siting of the control room complied with Recognized and Generally accepted Good Engineering Practices (RAGAGEP) when the employer failed to do any of the following;   (I) Conduct building siting evaluations for existing buildings intended for occupancy  (II) Evaluate how the control room could be impacted in the event of a blast  (III) Evaluate how the control room could be impacted by flammable vapor release.    This condition exposed employees to fire and explosion hazards.   (Example RAGAGEP for facility siting include, but not limited to API 752, paragraph 5.4,6.6 and 7.4)
Recent events (2)
  • — I (S) $12934
  • — Z (S) $9054

1910.119 E03 V

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address the hazards of facility siting:   (a) Dianal America Inc facility: On February 12 2018 and at times prior to, the employer failed to evaluate and address the hazards associated with locating the control room within 12 feet of process equipment/reactors that contain highly flammable chemicals. This condition exposed employees to explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 J02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $0.00 Reduced
29 CFR 1910.119(j)(2): The employer did not establish written procedures to maintain the on-going integrity of process equipment:   (a) Dianal America Inc facility: On or about February 12 2018 and at times prior, the employer failed to establish written inspection procedures to maintain a 16" KITZ motor operated gate valve   This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9054

1910.119 O01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $9054.00
29 CFR 1910.119(o)(1): The employer did not certify that they have evaluated compliance with the provisions of this section at least every three years:  (a) Dianal America inc facility: On February 12, 2018 and at times prior to, the employer did not certify that they have evaluated compliance with the Process safety management standard at least every three years.
Recent events (2)
  • — I (S) $9054
  • — Z (S) $9054

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $9054.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a)Dianal America Inc's facility: On February 12,2018 the employer did not develop, document and utilize procedures for the control of hazardous energy before conducting an inspection on a 16"  KITZ motor operated gate valve. This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (S) $9054
  • — Z (S) $9054

1910.147 C07 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $9054.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training has been accomplished and is being kept up to date.   (a) Dianal America Inc's facility: On February 12, 2018 and at times prior to, the employer did not certify that employee training for the control of hazardous energy had been accomplished.
Recent events (2)
  • — I (O) $9054
  • — Z (S) $9054