AUGUSTA, GA —
OSHA Inspection: O'CONNER CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of O'CONNER CONSTRUCTION, LLC in 1323 AUGUSTA WEST PARKWAY, AUGUSTA, GA 30901 (NAICS 238140). OSHA activity number 342973047.
Where did this inspection happen?
- Establishment
- O'CONNER CONSTRUCTION, LLC
- Site address
- 1323 AUGUSTA WEST PARKWAY
- City
- AUGUSTA
- State
- GA
- ZIP
- 30901
- Mailing
- 706 LAKE THURMOND COURT, NORTH AUGUSTA, SC 29841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $3880.00 · Current $2328.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked: On or about 2/22/2018 at 1323 W. Augusta Parkway Augusta, GA workers performing CMU block installation activities were observed exposed to 22-foot fall hazards to the concrete flooring below where the walk boards were not fully installed on the working levels.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.451 E01
- Issued
- Penalty
- Initial $3880.00 · Current $2328.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 2/22/2018 at 1323 W. Augusta Parkway Augusta, GA workers were exposed to fall hazards up to 22-feet above the concrete floor where observed accessing and egressing the scaffold during CMU block installation activities by way of the cross bracing and frame where no ladders were installed.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.451 H01
- Issued
- Penalty
- Initial $1885.00 · Current $1131.00 Reduced
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall: On or about 2/22/2018 at 1323 W. Augusta Parkway Augusta, GA workers performing CMU block installation activities that were on the ground below the scaffold were exposed to struck-by hazards where there were no toe boards installed. Potentially dropped items included but were not limited to block, hand tools, and materials.
Recent events (2)
- — I (S) $1131
- — Z (S) $1885
1926.452 C04
- Issued
- Penalty
- Initial $3880.00 · Current $2328.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur: On or about 2/22/2018 at 1323 W. Augusta Parkway Augusta, GA workers on the scaffold were observed performing CMU block installation activities that were exposed to fall hazards above 22-feet to the concrete flooring below where the connecting pins were not installed in the scaffold being loaded by the JCB 507 forklift.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1910.134 C02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103) On or about 2/22/2018 at 1323 W. Augusta Parkway Augusta, GA where the employer failed to provide workers with the Appendix D information where workers were provided dust masks for voluntary use
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342973047.