BRIDGETON, MO —
OSHA Inspection: CHARGING TECHNOLOGIES, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CHARGING TECHNOLOGIES, INC. in 4328 BRIDGETON INDUSTRIAL DRIVE, BRIDGETON, MO 63044 (NAICS 335999). OSHA activity number 342993284.
Where did this inspection happen?
- Establishment
- CHARGING TECHNOLOGIES, INC.
- Site address
- 4328 BRIDGETON INDUSTRIAL DRIVE
- City
- BRIDGETON
- State
- MO
- ZIP
- 63044
- Mailing
- 4328 BRIDGETON INDUSTRIAL DRIVE, BRIDGETON, MO 63044
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 22
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.137 C02 II
- Issued
- Abate by
- Penalty
- Initial $5691.00 · Current $4691.00 Reduced
General-duty citation text
29 CFR 1910.137(c)(2)(ii): Insulating equipment was not inspected for damage before each day's use and immediately following any incident that can reasonably be suspected of causing damage. Insulating gloves shall be given an air test, along with the inspection: Within the Production Department located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri: Insulating gloves were not inspected for damage before each day's use for employees performing electrical tests with voltages ranging between 120 VAC and 2,500 VAC, during the following, but not limited to, forklift battery charger production processes: a. The in-process inspection procedures for transformers, b. The final assembly electrical tests.
Recent events (3)
- — J (S) $4691
- — C (S) $5691
- — Z (S) $5691
1910.137 C02 VII
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.137(c)(2)(vii): Protective gloves were not worn over insulating gloves. Within the Production Department located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri: Protective gloves were not worn over insulating gloves to prevent damage for employees performing electrical tests with voltages ranging between 120 VAC and 2,500 VAC, during the following, but not limited to, forklift battery production process: a. The in-process inspection procedures for transformers, b. The final assembly electrical tests. In the alternative, 1910.335(a)(1)(iii) When the insulating capability of protective equipment may be subject to damage during use, the insulating material was not protected.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.137 C02 VIII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5: Within the Production Department located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri: The employer did not ensure that electrically insulated gloves that were provided to workers had been tested prior to first issue and within the maximum intervals in accordance with Table I-5.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.333 C02
- Issued
- Abate by
- Penalty
- Initial $5691.00 · Current $4691.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that qualified persons were capable of working safely on energized circuits and were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. Location: Within the Production Department located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri: Employees performing component electrical tests during the production of forklift battery chargers were not familiar with the proper use of precautionary techniques and personal protective equipment required while performing electrical tests with voltages ranging between 120 VAC and 2,500 VAC, during the following, but not limited to, forklift battery production process: a. The in-process inspection procedures for transformers, b. The final assembly electrical tests.
Recent events (3)
- — J (S) $4691
- — C (S) $5691
- — Z (S) $5691
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $8130.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation (P.O.O.) of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycles: Within the Transformer Department located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri: The points of operation for the two T & B Crimper Machines, m/n C13600 were inadequately guarded. The Ferro Magnetics Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 1007955, citation number 1, item number 9 and was affirmed as a final order on December 21, 2015, with respect to a workplace located at 4328 Bridgeton Industrial Park Drive, Bridgeton, Missouri.
Recent events (3)
- — J (R) $0
- — C (R) $8130
- — Z (R) $8130
More inspections in this industry (NAICS 335999)
ANDOVER, MA—2026-07-09
VICOR CORPORATION
WILLIAMSBURG, VA—2026-07-07
EATON CORPORATION
FRANKFORT, IL—2026-07-06
QUANTUM TECHNICAL SERVICES INC.
WILLIAMSBURG, VA—2026-06-23
EATON CORPORATION
HUMACAO, PR—2026-06-17
EEMCO LLC
More inspections in MO
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342993284.