Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPRINGSEAL INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPRINGSEAL INC. in 800 ENTERPRISE PARKWAY, RAVENNA, OH 44266 (NAICS 326199). OSHA activity number 343002002.

Watch Springseal INC. — free Get an email when a new federal OSHA severe-injury report for Springseal INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SPRINGSEAL INC.
Site address
800 ENTERPRISE PARKWAY
City
RAVENNA
State
OH
ZIP
44266
Mailing
800 ENTERPRISE PARKWAY, RAVENNA, OH 44266
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.219 E01

Serious Gravity 5 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $5497.00 · Current $2199.00 Reduced
29 CFR 1910.219(e)(1): 1910.219(e)(1)(i) Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed  by guards conforming to the requirements  specified in 29 CFR1910.219 (m) and (o):      On or about 3/8/18, the employer failed to ensure that belts, including but not limited to the puller belts on line #4, had guarding methods in place. The puller was completely open exposing the belts ingoing nip point, and the sides.
Recent events (2)
  • — I (S) $2198.8
  • — Z (S) $5497

1910.303 B07

Serious Gravity 5 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $5497.00 · Current $2199.00 Reduced
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:    On or about 3/8/2018, the employer failed to ensure that electrical connections, including but not limited to, the heater bands attached to the extrusion dies, on extruder lines #1 through #7, were installed in a workmanlike manner. The heater band conductors were connected with wire nuts, and the wires were secured to the machines with metal Irwin spring clamps.
Recent events (2)
  • — I (S) $2198.8
  • — Z (S) $5497

1910.303 G02 I

Serious Gravity 5 7 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about 3/8/2018, the employer failed to ensure that electrical connections, including but not limited to, the 240V heater bands attached to the extrusion dies, on extruder lines #1 through #7, were guarded against accidental contact. The heater band conductors were connected with wire nuts, and the wires were secured to the machines with metal Irwin spring clamps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343002002.