Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CELESTINO ACOSTA

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CELESTINO ACOSTA in 5355 S MCCURRY WAY, MERIDIAN, ID 83642 (NAICS 423330). OSHA activity number 343004396.

Watch Celestino Acosta — free Get an email when a new federal OSHA severe-injury report for Celestino Acosta is published. One employer, no account, unsubscribe in one click.
Establishment
CELESTINO ACOSTA
Site address
5355 S MCCURRY WAY
City
MERIDIAN
State
ID
ZIP
83642
Mailing
1607 E SHARONS LOOP APARTMENT 103, NAMPA, ID 83686
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2217.00 · Current $1108.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  On or about March 5, 2018, employees performing roofing activities were exposed to a fall hazard while working on a 6 in 12 pitch roof with 10 in 12 pitch dormers on this residential structure without a means of fall protection.   Note: Abatement certification IS NOT required for this item.
Recent events (2)
  • — I (S) $1108
  • — Z (S) $2217

1926.503 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii):  a) On or about March 5, 2018 and at times prior thereto, the employer did not provide any, adequate and/or effective fall protection training for his employee performing roofing work at elevated areas of a residential structure.   Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343004396.