Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHAWN SILVER CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SHAWN SILVER CONSTRUCTION in 4035 TANEIL DR, MANHATTAN, KS 66502 (NAICS 238130). OSHA activity number 343017711.

Watch Shawn Silver Construction — free Get an email when a new federal OSHA severe-injury report for Shawn Silver Construction is published. One employer, no account, unsubscribe in one click.
Site address
4035 TANEIL DR
City
MANHATTAN
State
KS
ZIP
66502
Mailing
1311 N MILTON PO BOX 131, AUBURN, KS 66402
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  In the front of the building: Employees engaged in dormer sheeting utilized a ladder that was extended approximately one (1) foot above the eave to access the roof. Employees were exposed to a fall hazard of up to 10 feet to the ground below.
Recent events (2)
  • — I (S) $1663.2
  • — Z (S) $2772

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1926.501(b)(13): Employees engaged in residential construction activities 6 feet (1.8m) or more above the lower levels were not protected by guardrail systems, safety net systems, or personal fall arrest systems:  On the roof in the front of the building: Employees engaged in residential dormer sheeting activities from a 6:12 pitch roof were exposed to fall hazards of approximately 10 feet from the eave of the residence to the ground below in that fall protection was not provided/utilized.
Recent events (2)
  • — I (S) $1663.2
  • — Z (S) $2772

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): At this establishment, the employer did not certify that each operator has been trained and evaluated to operate the powered industrial truck as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.  The employer did not ensure that a certification of training and evaluation had been created pertaining to the forklift operator.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  In the front of the building at the breaker box/receptacle box: The light green AWG 12/3 extension cord providing electrical power to a DeWalt crosscut saw did not have the outer insulation firmly attached to the male end of the cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343017711.