BLACKWOOD, NJ —
OSHA Inspection: ENGINE DISTRIBUTORS INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ENGINE DISTRIBUTORS INC. in 400 UNIVERSITY CT., BLACKWOOD, NJ 08012 (NAICS 423830). OSHA activity number 343020764.
Where did this inspection happen?
- Establishment
- ENGINE DISTRIBUTORS INC.
- Site address
- 400 UNIVERSITY CT.
- City
- BLACKWOOD
- State
- NJ
- ZIP
- 08012
- Mailing
- 400 UNIVERSITY CT., BLACKWOOD, NJ 08012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 41
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.37 B04
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $2560.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Warehouse: Directional exit signs were not posted, that would indicate to employees the direction to travel to the nearest exit, on or about 3/15/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $2560
- — Z (S) $3880
1910.101 B
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $4268.00 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) West end of the warehouse: Oxygen cylinders were placed 3 inches from liquefied petroleum cylinders and acetylene cylinders and were not properly secured to prevent the cylinders from being knocked over, on or about 3/15/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $4268
- — Z (S) $6467
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $6467.00 · Current $4268.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: a) West end of the warehouse: Oxygen compressed gas cylinders were stored 3 inches from waste oil drum containing oil, liquefied petroleum cylinders and acetylene compressed gas cylinder, on or about 3/15/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $4268
- — Z (S) $6467
1910.253 B04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire. a) West end of the warehouse: Oxygen compressed gas cylinders were stored 3 inches from waste oil drum, liquefied petroleum cylinders and acetylene compressed gas cylinder, on or about 3/15/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a) West end of warehouse: Oxygen compressed gas cylinders were stored 3 inches from a waste oil drum containing oil, liquefied petroleum cylinders and acetylene compressed gas cylinders, on or about 3/15/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ENGINE DISTRIBUTORS INC.
Gambrills, MD—1983-04-06
ENGINE DISTRIBUTORS INC
View ENGINE DISTRIBUTORS INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423830)
CLOVERDALE, VA—2026-07-10
CUMMINS SALES AND SERVICE
MOUNT BRADDOCK, PA—2026-07-01
HAZEMAG USA INC
CALEDONIA, MI—2026-07-01
TRACTOR SUPPLY COMPANY OF MICHIGAN LLC
FRESNO, CA—2026-06-30
WHOLESALE EQUIPMENT OF FRESNO, INC.
COLUMBUS, OH—2026-06-25
MIDWEST MOTOR SUPPLY CO. INC.
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source