OSHA Inspection: LOYAL PALLET, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOYAL PALLET, INC in 706 NORTH MAIN STREET, LOYAL, WI 54446 (NAICS 321920). OSHA activity number 343032694.

Watch Loyal Pallet, INC — free Get an email when a new federal OSHA severe-injury report for Loyal Pallet, INC is published. One employer, no account, unsubscribe in one click.
Establishment
LOYAL PALLET, INC
Site address
706 NORTH MAIN STREET
City
LOYAL
State
WI
ZIP
54446
Mailing
P.O. BOX 185, LOYAL, WI 54446
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
3
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1665.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) In the production area; The employer did not develop, document and utilize procedures for hazardous energy control.
Recent events (2)
  • — I (S) $1665
  • — Z (S) $2772

1910.147 C05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:  (a) In the production area; The employer did not provide the employees the required hardware to ensure hazardous energy sources could not unintentionally start-up causing injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  (a) In the production area; The employer did not train the employees on the hazardous energy control program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) In the production area; The employer did not certify that the operator of the powered industrial vehicle (PIV) had been trained.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343032694.