Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ZENGER PARTNERS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ZENGER PARTNERS, LLC in 1881 KEMORE AVENUE, KENMORE, NY 14217 (NAICS 323111). OSHA activity number 343033817.

Watch Zenger Partners, LLC — free Get an email when a new federal OSHA severe-injury report for Zenger Partners, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1881 KEMORE AVENUE
City
KENMORE
State
NY
ZIP
14217
Mailing
1881 KEMORE AVENUE, KENMORE, NY 14217
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
14
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3141.00 · Current $750.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) On or about 03/23/18 throughout the print shop; employees were engaged in service and maintenance of printing equipment and associated machine, such as but not limited to, repairing stitcher heads, replacing cutter blades, greasing and lubrication, replacing drive belts, rollers and were exposed to caught between hazards when the employer did not have an energy control program which included energy control procedures and periodic inspections.      ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $750
  • — C (S) $3141
  • — Z (S) $3141

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section;   a) On or about 03/23/18 throughout the print shop; employees engaged in service and maintenance of printing equipment and associated machine, such as but not limited to, repairing stitcher heads, replacing cutter blades, greasing and lubrication, replacing drive belts, rollers and were exposed to caught between hazards when the employer allowed the use of emergency stop buttons and interlocks instead of requiring the use of an energy control procedure which included preventing the release of hazardous energy by operating all energy isolating devices and the use of lock out or tag out devices for control.     ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2513.00 · Current $750.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, of the stitcher/cutter;     a) On or about 03/22/18 in the print shop; employees were exposed to a caught between hazard created by the two stitching heads when the guard/cover for the stitching area on the stitcher machine was missing.      b) On or about 03/22/18 in the print shop; employees were exposed to a struck by hazard, the falling cover of the cutter area, when the raised cover was prevented from falling by inserting a piece of aluminum pipe instead of the designed raised cover protection mechanism.        NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $750
  • — C (S) $2513
  • — Z (S) $2513

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343033817.